All bid deadlines are 11:59pm Pacific Time the date of the bid deadline listed unless otherwise noted.

school Prairie Grove School Dist 23
IFCB Posted : Jan 8, 2026
Bid Deadline : Monday, Feb 9, 2026

Questions Due By : Monday, Jan 12, 2026
Applicant Address : Prairie Grove, AR 72753
IFCB ID : 260013098

IFCB Requirements :

·         Before the listed deadlines, all Questions and Bids must be submitted using the on-line IFCB system. Bids submitted before the bid deadline outside of this system will be disqualified. If the system is down before the deadline, please email your bid to info@crwconsulting.com or fax it to 918.445.0049. Bids or questions submitted in this fashion will be disqualified if the on-line system is active at the time of submission. The applicant reserves the right to request and obtain bids outside of the website system if the bid deadline has passed and zero or one bid is received (the intent for this is to follow USAC guidance on obtaining cost-effective bids).

·        For all requested services and/or products listed on this IFCB: proposals that include generic/encyclopedic price lists will be considered non-responsive and will be disqualified. SPAM and/or robotic responses will not be considered valid bid responses and will be disqualified from consideration.

 

·         Bidder must agree to participate in USF Program (AKA “E-rate”) for the corresponding funding year.

 

·         Please include the correct Service Provider Identification Number (SPIN) on your bid.

 

·         By submitting a bid, bidder certifies that the bidder does have a valid (non-red light status) SPIN for the E-rate program at the time of submission. Should the Applicant discover that the bidder is on red light status, or if the FCC classifies the bidder as on red-light status before work is performed and invoices are paid, the contract will be null and void and the applicant will have no payment obligations to the bidder.

 

·         Bidder is expected to provide the lowest corresponding price per E-rate rules.  See https://www.usac.org/e-rate/service-providers/step-2-responding-to-bids/lowest-corresponding-price/ for details.

 

·         Contracts must not prohibit SPIN changes.

 

·         Bidder must agree to provide the Applicant the choice of discount methods (SPI or BEAR).

 

·         Bidder will be automatically disqualified if the District determines that the bidding company has offered any employee of the District any individual gift of more than $20 or gifts totaling more than $50 within a 12 month period. This does not apply to the recent FCC exemptions of the Gift Rule for the COVID pandemic.

 

·         All contracts awarded will be contingent upon E-rate funding and final board approval.  The applicant may choose to do all or part of the project upon funding notification.

 

·         All applicable fees, surcharges, and taxes must be identified on the bid. E-rate rules require the applicants to evaluate the price of eligible goods and services that will be listed on the 471 application during the competitive bidding process. Fees and surcharges that apply but are not listed on the bid will be the responsibility of the bidding company, should their bid be awarded.

 

·         If there is a request to purchase or lease new equipment, either Category Two or Category One,  listed on this IFCB the applicant will accept bids for functionally equivalent equipment.

 

·         E-rate rules require applicants to evaluate the cost of eligible goods and services, and to cost-allocate out the amount for ineligible services from their funding request. If your company will be bidding internet access service, please identify the amount to be cost-allocated out for the ineligible services – email service, web hosting, content filtering, or other bundled ineligible services.

·         INTERNET ACCESS DISQUALIFICATION FACTOR: Bids submitted for services to an incorrect address will be disqualified.

 

·         INTERNET ACCESS DISQUALIFICATION FACTOR: Your bid must identify the bandwidth you are proposing and associated price or your bid will be disqualified.

 

·         INTERNET ACCESS DISQUALIFICATION FACTOR: Any and all installation charges must be identified on your bid. If you submit a bid indicating that installation charges may apply without listing those charges, we will consider your bid incomplete and disqualify your bid.

 

·         LEASED WIDE AREA NETWORK CIRCUITS DISQUALIFICATION FACTOR: Bids submitted for services to an incorrect address will be disqualified.

 

·         LEASED WIDE AREA NETWORK CIRCUITS DISQUALIFICATION FACTOR: Any and all installation charges must be identified on your bid. If you submit a bid indicating that installation charges may apply without listing those charges, we will consider your bid incomplete and disqualify your bid.

 

·         DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: The applicant will not accept bids from manufacturers of equipment deemed a national security threat by the Federal Communications Commission. The list of prohibited equipment is available here: https://www.fcc.gov/supplychain/coveredlist . Vendors that submit bids that includes these manufacturers will have their bid disqualified.

 

·         DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Vendors must complete and include the C2 Cover Page with their bid. Bids received without the cover page will be disqualified.

·         DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: It will be the bidder’s responsibility to provide documentation about the compatibility requirements listed in this IFCB. Vendors that submit bids without documentation demonstrating the required compatibility listed in this IFCB will have their bids disqualified, unless that vendor has bid the preferred make/model number listed.

·         DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Applicant will not accept bids for refurbished equipment. Any bids containing refurbished equipment will be disqualified.

 

·         DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Service providers are required to bid an entire Project A, Project B and/or Project C.  Bids for individual components, or bids that do not include all of the requested items for the project will be disqualified.

 

 


Services and Equipment Requested :

UPDATE 1/12/26 - THE BID DEADLINE HAS BEEN UPDATED TO 2/9/26. THE MAKE/MODEL FOR IC PROJECT A, SWITCHES HAS BEEN UPDATED FROM ARUBA 2930 TO ARUBA 2930F

UPDATE 01/08/26 - IC PROJECT B, QUANTITIES FOR THE WAPS HAVE BEEN UPDATED FROM 20 TO 30. 

Category One:

Internet Access - District currently has 1 GB bandwidth and would like to increase to 2.5 GB. The  terminating address for this circuit is located at 102 E. Buchanan Street, Prairie Grove AR 72753.  Vendors should include pricing for 1 GB and 2.5 GB bandwidth.

 

After the initial term, or after any voluntary renewal terms are executed, the Vendor must offer up to 12 months of a month-to-month service if the Applicant decides to transition to a new service provider. Vendor must list that monthly cost as part of their proposal.

 

E-rate rules require applicants to evaluate the cost of eligible goods and services, and to cost-allocate out the amount for ineligible services from their funding request. If your company will be bidding internet access service, please identify the amount to be cost-allocated out for the ineligible services – email service, web hosting, content filtering, or other bundled ineligible services.

INTERNET ACCESS DISQUALIFICATION FACTOR: Bids submitted for services to an incorrect address will be disqualified.

 

INTERNET ACCESS DISQUALIFICATION FACTOR: Your bid must identify the bandwidth you are proposing and associated price or your bid will be disqualified.

 

INTERNET ACCESS DISQUALIFICATION FACTOR: Any and all installation charges must be identified on your bid. If you submit a bid indicating that installation charges may apply without listing those charges, we will consider your bid incomplete and disqualify your bid.

 

Leased Wide Area Network Circuits – two connections any delivery/technology type.  Leased dark fiber bidders should bid 6 fiber strands. Lit leased fiber bidders should bid 10 GB. These connections are from the hub located at 102 E. Buchanan Street, Prairie Grove AR, 72753 to the following sites:

1.       240 Viney Grove Road, Prairie Grove, AR 72753

2.       806 N. Mock Street, Prairie Grove, AR 72753

 

LEASED WIDE AREA NETWORK CIRCUITS DISQUALIFICATION FACTOR: Bids submitted for services to an incorrect address will be disqualified.

 

LEASED WIDE AREA NETWORK CIRCUITS DISQUALIFICATION FACTOR: Any and all installation charges must be identified on your bid. If you submit a bid indicating that installation charges may apply without listing those charges, we will consider your bid incomplete and disqualify your bid.

 

Operations and Maintenance services – two connections, from 102 E. Buchanan Street, Prairie Grove AR, 72753 to the following sites:

1.       240 Viney Grove Road, Prairie Grove, AR 72753

2.       806 N. Mock Street, Prairie Grove, AR 72753

 

 

Category Two:

INTERNAL CONNECTIONS

No installation is needed.

 

IC PROJECT A – SWITCHES

No licensing needed for the switches.

Type of Equipment

Quantity Vendor Should Bid

 

Preferred Make/Manufacturer

Antennas, Connectors and Related Components

10

Aruba 10 GB SFP’s

Switches

20

Aruba 2930 2930F 48 port POE+ 740 watt

 

NOTE: We are requesting switch licenses on this IFCB, which sometimes may be categorized as BMIC or MIBS by USAC (the BMIC and MIBS boxes on the 470 have been checked to cover this scenario).

 

COMPATIBILITY REQUIREMENT:

Equipment must be compatible with existing Aruba Central.

 

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: It will be the bidder’s responsibility to provide documentation about the compatibility requirements listed in this IFCB. Vendors that submit bids without documentation demonstrating the required compatibility listed in this IFCB will have their bids disqualified, unless that vendor has bid the preferred make/model number listed.

 

IC PROJECT B – WAPs

 

Type of Equipment

Quantity Vendor Should Bid

 

Preferred Make/Manufacturer

Antennas, Connectors and Related Components

30

Aruba AP Mounts – MNT-B Suspended ceiling mounts

Wireless Access Points

20 30

Aruba 635 AP’s with 5 year Aruba Central licensing

WAP Licensing

165

5 year Aruba Central licensing for existing WAPs

 

NOTE: We are requesting switch licenses on this IFCB, which sometimes may be categorized as BMIC or MIBS by USAC (the BMIC and MIBS boxes on the 470 have been checked to cover this scenario).

 

COMPATIBILITY REQUIREMENT:

Equipment must be compatible with existing Aruba Central.

 

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: It will be the bidder’s responsibility to provide documentation about the compatibility requirements listed in this IFCB. Vendors that submit bids without documentation demonstrating the required compatibility listed in this IFCB will have their bids disqualified, unless that vendor has bid the preferred make/model number listed.

 

IC PROJECT C – UPS

 

Type of Equipment

Quantity Vendor Should Bid

 

Preferred Make/Manufacturer

UPS/Battery Backup

3

Eaton TrippLite 220VA 1950W

 

 

COMPATIBILITY REQUIREMENT:

Equipment must be compatible with existing Aruba Central.

 

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: The applicant will not accept bids from manufacturers of equipment deemed a national security threat by the Federal Communications Commission. The list of prohibited equipment is available here: https://www.fcc.gov/supplychain/coveredlist . Vendors that submit bids that includes these manufacturers will have their bid disqualified.

 

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Vendors must complete and include the C2 Cover Page with their bid. Bids received without the cover page will be disqualified.

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: It will be the bidder’s responsibility to provide documentation about the compatibility requirements listed in this IFCB. Vendors that submit bids without documentation demonstrating the required compatibility listed in this IFCB will have their bids disqualified, unless that vendor has bid the preferred make/model number listed.

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Applicant will not accept bids for refurbished equipment. Any bids containing refurbished equipment will be disqualified.

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Service providers are required to bid an entire Project A, Project B and/or Project C.  Bids for individual components, or bids that do not include all of the requested items for the project will be disqualified.

 

 


There is an additional document associated with this IFCB. Please click the buttons to download the document.

2026_C2_Bidding_Instructions_220.pdf
PRAIRIE_GROVE_C2_COVER_PAGE6.pdf

You need to login / register to upload bid.

Questions Received with Applicant Answers   ( Ask Questions? )




Will the Aruba 2930s requested need to stack with existing Aruba 2930s, or will the switches requested be replacing entire switch stack/single switch locations?

Answer:

These are mostly going into a new construction. So they won't be stacking with existing 2930's.

Will the 2930's need to stack at all? What type of 10gb optics do you need? Single-mode or multi-mode?

Answer:
They may stack, it depends where they are installed. Single mode SFP’s.

Are you looking for the 2930F with fixed power supplies or the 2930M with the removable power supplies?

Answer:
We are looking for the 2930f.

For the SFPs, do you need long range/single mode optics or short range/multimode optics? You said you don't want licensing for the 20 switches, but they want them to work in Central. Do you have existing Central licenses or do you need more attached to this quote?

Answer:

Single mode sfp's, and no on the switch licenses, we have been managing our switches outside of Aruba Central.