All bid deadlines are 11:59pm Pacific Time the date of the bid deadline listed unless otherwise noted.
· Before the listed deadlines, all Questions and Bids must be submitted using the on-line IFCB system. Bids submitted before the bid deadline outside of this system will be disqualified. If the system is down before the deadline, please email your bid to info@crwconsulting.com or fax it to 918.445.0049. Bids or questions submitted in this fashion will be disqualified if the on-line system is active at the time of submission. The applicant reserves the right to request and obtain bids outside of the website system if the bid deadline has passed and zero or one bid is received (the intent for this is to follow USAC guidance on obtaining cost-effective bids).
· For all requested services and/or products listed on this IFCB: proposals that include generic/encyclopedic price lists will be considered non-responsive and will be disqualified. SPAM and/or robotic responses will not be considered valid bid responses and will be disqualified from consideration.
· Bidder must agree to participate in USF Program (AKA “E-rate”) for the corresponding funding year.
· Please include the correct Service Provider Identification Number (SPIN) on your bid.
· By submitting a bid, bidder certifies that the bidder does have a valid (non-red light status) SPIN for the E-rate program at the time of submission. Should the Applicant discover that the bidder is on red light status, or if the FCC classifies the bidder as on red-light status before work is performed and invoices are paid, the contract will be null and void and the applicant will have no payment obligations to the bidder.
· Bidder is expected to provide the lowest corresponding price per E-rate rules. See https://www.usac.org/e-rate/service-providers/step-2-responding-to-bids/lowest-corresponding-price/ for details.
· Contracts must not prohibit SPIN changes.
· Bidder must agree to provide the Applicant the choice of discount methods (SPI or BEAR).
· Bidder will be automatically disqualified if the District determines that the bidding company has offered any employee of the District any individual gift of more than $20 or gifts totaling more than $50 within a 12 month period. This does not apply to the recent FCC exemptions of the Gift Rule for the COVID pandemic.
· All contracts awarded will be contingent upon E-rate funding and final board approval. The applicant may choose to do all or part of the project upon funding notification.
· All applicable fees, surcharges, and taxes must be identified on the bid. E-rate rules require the applicants to evaluate the price of eligible goods and services that will be listed on the 471 application during the competitive bidding process. Fees and surcharges that apply but are not listed on the bid will be the responsibility of the bidding company, should their bid be awarded.
· If there is a request for Internal Connections (Category Two) equipment, or Category One equipment listed on this IFCB the applicant will accept bids for functionally equivalent equipment.
· DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: The applicant will not accept bids from manufacturers of equipment deemed a national security threat by the Federal Communications Commission. The list of prohibited equipment is available here: https://www.fcc.gov/supplychain/coveredlist. Vendors that submit bids that include these manufacturers will have their bids disqualified.
· DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Vendors must complete and include the C2 Cover Page with their bid. Bids received without the cover page will be disqualified.
· DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Service providers are required to bid an entire Project A or Project B. Bids for individual components of a single project, or bids that do not include all of the requested items for a single project will be disqualified.
· DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Applicant will not accept bids for refurbished equipment. Any bids containing refurbished equipment will be disqualified.
· DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: It will be the bidder’s responsibility to provide documentation about the compatibility requirements listed in this IFCB. Vendors that submit bids without documentation demonstrating the required compatibility listed in this IFCB will have their bids disqualified, unless that vendor has bid the preferred make/model number listed.
· DISQUALIFICATION FACTOR BMIC: Vendors must complete and include the C2 Cover Page with their bid. Bids received without the cover page will be disqualified.
· DISQUALIFICATION FACTOR BMIC: Maintenance bids listing only an hourly rate and not a monthly or annual total will be disqualified. Vendors quoting an hourly rate are required to also a) confirm that you have the ability/expertise to maintain all of the equipment listed and b) propose a number of hours at a particular rate monthly to properly maintain the entire list of equipment. Bids that contain only hourly rates, without confirmation that the company can service the list of equipment, or without a monthly total will be disqualified.
INTERNAL CONNECTIONS-Project A
No Installation needed
|
Type of Equipment |
Quantity Vendor Should Bid
|
Preferred Make/Manufacturer |
|
Wireless Access Points |
16 |
Cisco Catalyst 9120AX Series – EDU C9120AXI-B-EDU |
|
Wireless Access Points |
16 |
Wireless Cisco DNA On-Prem Essentials, 9120 Tracking CDNA-E-C9120 |
|
Wireless Access Points |
16 |
C9120AX Cisco DNA On-Prem Essential-5YR DNA-E-5Y-C9120 |
|
Wireless Access Points |
16 |
Wireless Cisco DNA On-Prem Essential, Term, EDU Lic AIR-DNA-EDU-E |
|
Wireless Access Points |
16 |
Wireless Cisco DNA On-Prem Essential, 5Y Term EDU Lic EDU-DNA-E-5Y |
|
Wireless Access Points |
16 |
Wireless Cisco DNA On-Prem Essential, Term, Tracker Lic AIR-DNA-E-T |
|
Wireless Access Points |
16 |
Wireless Cisco DNA On-Prem Essential, 5Y Term, Tracker Lic AIR-DNA-E-T-5Y |
|
Wireless Access Points |
16 |
Capwap software for Catalyst 9120AX SW9120AX-CAPWAP-K9 |
|
Antennas, Connectors and Related Components |
16 |
Ceiling Grid Clip for APs & Cellular Gateways-Recessed AIR-AP-T-RAIL-R |
|
Antennas, Connectors and Related Components |
16 |
802.11 AP Low Profile Mounting Bracket (Default) AIR-AP-BRACKET-1 |
|
Wireless Access Points |
16 |
Wireless DNA Perpetual Network Stack Essentials AIR-DNA-NWSTACK-E |
|
Wireless Access Points |
16 |
Network Plug-n-Play Connect for zero-touch device deployment NETWORK-PNP-LIC |
|
Switches |
2 |
Catalyst 9300 24-port PoE+, K12 C9300-24P-EDU |
|
Switches |
2 |
C9300 DNA Essentials, 24-Port Term Licenses C9300-DNA-E-24 |
|
Switches |
2 |
C9300 DNA Essentials, 24-Port, 5 Year Term License C9300-DNA-E-24-5Y |
|
Switches |
2 |
C9300 Network Essentials, 24-port license C9300-NW-E-24 |
|
Switches |
2 |
Cisco Catalyst 9300 XE 17.12 UNIVERSAL SC9300UK9-1712 |
|
UPS/Battery Backup |
2 |
715W AC 80+ platinum Config 1 Power Supply PWR-C1-715WAC-P |
|
Cabling |
2 |
North America AC Type A Power Cable CAB-TA-NA |
|
Cabling |
2 |
50CM Type 1 Stacking Cable STACK-T1-50CM |
|
Cabling |
2 |
Catalyst Stack Power Cable 30 CM CAB-SPWR-30CM |
|
Antennas, Connectors and Related Components |
2 |
Cisco Catalyst Type 1 Network ModuleBlank NM-BLANK-T1 |
|
Antennas, Connectors and Related Components |
2 |
RUBBER FEET FOR TABLE TOP SETUP 9200 and 93xx C9K-ACC-RBFT |
|
Antennas, Connectors and Related Components |
2 |
12-24 and 10-32 SCREWS FOR RACK INSTALLATION, C9K-ACC-SCR-4 |
|
Antennas, Connectors and Related Components |
2 |
1RU CABLE MANAGEMENT GUIDES 9200 and 9300 CAB-GUIDE-1RU |
|
Switches |
2 |
Network Plug-n-Play Connect for zero-touch device deployment NETWORK-PNP-LIC |
|
Switches |
1 |
Catalyst 9300 48-port PoE+, K12 C9300-48P-EDU |
|
Switches |
1 |
C9300 DNA Essentials, 48-Port, 5Year Term Licenses C9300-DNA-E-48 |
|
Switches |
1 |
C9300 DNA Essentials, 48-Port C9300-DNA-E-48-5Y |
|
Switches |
1 |
C9300 Network Essentials, 48-port license C9300-NW-E-48 |
|
Switches |
1 |
Cisco Catalyst 9300 XE 17.12UNIVERSAL SC9300UK9-1712 |
|
UPS/Battery Backup |
1 |
715W AC 80+ platinum Config 1 Power Supply PWR-C1-715WAC-P |
|
Cabling |
1 |
1North America AC Type A Power Cable CAB-TA-N1A |
|
Cabling |
1 |
50C1M Type 1 Stacking Cable STACK-T1-50CM |
|
Cabling |
1 |
Catal1yst Stack Power Cable 30 CM CAB-SPWR-30CM |
|
Antennas, Connectors and Related Components |
1 |
Cisco Catalyst Type 1 Network Module Blank NM-BLANK-T1 |
|
Antennas, Connectors and Related Components |
1 |
RUBBER FEET FOR TABLE TOP SETUP 9200 and 93xx C9K-ACC-RBFT |
|
Antennas, Connectors and Related Components |
1 |
12-24 and 10-32 SCREWS FOR RACK INSTALLATION, C9K-ACC-SCR-4 |
|
Antennas, Connectors and Related Components |
1 |
1RU CABLE MANAGEMENT GUIDES 9200 and 9300 CAB-GUIDE-1RU |
|
Switches |
1 |
Network Plug-n-Play Connect for zero-touch device deployment NETWORK-PNP-LIC |
NOTE: We are requesting AP and Switch licenses on this IFCB, which sometimes may be categorized as BMIC or MIBS by USAC (the BMIC and MIBS boxes on the 470 have been checked to cover this scenario).
COMPATIBILITY REQUIREMENT:
Equipment must be compatible with the existing Cisco network.
DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: The applicant will not accept bids from manufacturers of equipment deemed a national security threat by the Federal Communications Commission. The list of prohibited equipment is available here: https://www.fcc.gov/supplychain/coveredlist. Vendors that submit bids that include these manufacturers will have their bids disqualified.
DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Vendors must complete and include the C2 Cover Page with their bid. Bids received without the cover page will be disqualified.
DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Service providers are required to bid an entire Project A or Project B. Bids for individual components of a single project, or bids that do not include all of the requested items for a single project will be disqualified.
DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Applicant will not accept bids for refurbished equipment. Any bids containing refurbished equipment will be disqualified.
DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: It will be the bidder’s responsibility to provide documentation about the compatibility requirements listed in this IFCB. Vendors that submit bids without documentation demonstrating the required compatibility listed in this IFCB will have their bids disqualified, unless that vendor has bid the preferred make/model number listed.
INTERNAL CONNECTIONS-Project B
No Installation needed
|
Type of Equipment |
Quantity Vendor Should Bid
|
Preferred Make/Manufacturer |
|
Firewall Service and Components |
1 |
Cisco Secure Firewall 3105 NGFW Appliance 1U FPR3105-NGFW-K9 |
|
Firewall Service and Components |
1 |
Cisco Secure Firewall 3105 TD; Malware and URL License FPR3105T-TMC |
|
Firewall Service and Components |
1 |
Cisco Secure Firewall 3105 TD; AMP & URL Filtering 5 year Sub L-FPR3105T-TMC-5Y |
|
UPS/Battery Backup |
1 |
Cisco Secure Firewall 3K Series 400W AC Power Supply FPR3K-PWR-AC-400 |
|
Cabling |
2 |
AC Power Cord (North America); C13; NEMA 5-15P; 2.1m CAB-AC |
|
Firewall Service and Components |
1 |
Threat Defense software v7.4 for 3100 Series Appliances SF-F3K-TD7.4-K9 |
|
Firewall Service and Components |
1 |
Cisco Secure Firewall 3K Series 900GB FPR3K-SSD900 |
|
Antennas, Connectors and Related Components |
1 |
Cisco Secure Firewall 3100 Slide Rail Kit FPR3K-SLIDE-RAILS |
|
Firewall Service and Components |
1 |
Cisco Secure Firewall 3105 Base Lic FPR3105-BSE |
|
Antennas, Connectors and Related Components |
2 |
Cisco Secure Firewall 3K Series Fan Tray FPR3K-FAN |
|
Antennas, Connectors and Related Components |
1 |
Cisco Secure Firewall 3100 Network Module Blank Slot Cover FPR3K-NM-BLANK |
|
Cabling |
1 |
Console Cable 6ft with RJ45 and DB9F CAB-CONS-RJ45-DB9 |
|
Firewall Service and Components |
1 |
Cisco Secure Firewall 3K Series 900GB FPR3K-SSD900 |
NOTE: We are requesting Firewall licenses on this IFCB, which sometimes may be categorized as BMIC or MIBS by USAC (the BMIC and MIBS boxes on the 470 have been checked to cover this scenario).
COMPATIBILITY REQUIREMENT:
Equipment must be compatible with the existing Cisco network.
DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: The applicant will not accept bids from manufacturers of equipment deemed a national security threat by the Federal Communications Commission. The list of prohibited equipment is available here: https://www.fcc.gov/supplychain/coveredlist. Vendors that submit bids that include these manufacturers will have their bids disqualified.
DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Vendors must complete and include the C2 Cover Page with their bid. Bids received without the cover page will be disqualified.
DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Service providers are required to bid an entire Project A or Project B. Bids for individual components of a single project, or bids that do not include all of the requested items for a single project will be disqualified.
DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Applicant will not accept bids for refurbished equipment. Any bids containing refurbished equipment will be disqualified.
DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: It will be the bidder’s responsibility to provide documentation about the compatibility requirements listed in this IFCB. Vendors that submit bids without documentation demonstrating the required compatibility listed in this IFCB will have their bids disqualified, unless that vendor has bid the preferred make/model number listed.
BASIC MAINTENANCE OF INTERNAL CONNECTIONS (BMIC):
The District would like a manufacturer’s support contract for these items:
|
Type of Equipment |
Quantity Vendor Should Bid
|
Preferred Make/Manufacturer |
|
Firewall Service and Components |
1 |
SOLN SUPP 24X7X4 Cisco Secure Firewall - 5 Year CON-SSSNP-FPR3105N |
DISQUALIFICATION FACTOR BMIC: Vendors must complete and include the C2 Cover Page with their bid. Bids received without the cover page will be disqualified.
DISQUALIFICATION FACTOR BMIC: Maintenance bids listing only an hourly rate and not a monthly or annual total will be disqualified. Vendors quoting an hourly rate are required to also a) confirm that you have the ability/expertise to maintain all of the equipment listed and b) propose a number of hours at a particular rate monthly to properly maintain the entire list of equipment. Bids that contain only hourly rates, without confirmation that the company can service the list of equipment, or without a monthly total will be disqualified.
| 2026_C2_Bidding_Instructions_139.pdf |
| Spring_Hill_C2_COVER_PAGE1.pdf |
Answer:
All of the documents related to this IFCB/470 are posted on the IFCB for Spring Hill. There are two additional documents you can download at the bottom of the IFCB.