All bid deadlines are 11:59pm Pacific Time the date of the bid deadline listed unless otherwise noted.

school Springfield School District
IFCB Posted : Oct 21, 2025
Bid Deadline : Tuesday, Dec 2, 2025

Questions Due By : Thursday, Oct 30, 2025
Applicant Address : Springfield, MO 65802
IFCB ID : 260003523

IFCB Requirements :

·       Before the listed deadlines, all Questions and Bids must be submitted using the on-line IFCB system. Bids submitted before the bid deadline outside of this system will be disqualified. If the system is down before the deadline, please email your bid to info@crwconsulting.com or fax it to 918.445.0049. Bids or questions submitted in this fashion will be disqualified if the on-line system is active at the time of submission. The applicant reserves the right to request and obtain bids outside of the website system if the bid deadline has passed and zero or one bid is received (the intent for this is to follow USAC guidance on obtaining cost-effective bids).

·      For all requested services and/or products listed on this IFCB: proposals that include generic/encyclopedic price lists will be considered non-responsive and will be disqualified. SPAM and/or robotic responses will not be considered valid bid responses and will be disqualified from consideration.

 

·       Bidder must agree to participate in USF Program (AKA “E-rate”) for the corresponding funding year.

 

·       Please include the correct Service Provider Identification Number (SPIN) on your bid.

 

·       By submitting a bid, bidder certifies that the bidder does have a valid (non-red light status) SPIN for the E-rate program at the time of submission. Should the Applicant discover that the bidder is on red light status, or if the FCC classifies the bidder as on red-light status before work is performed and invoices are paid, the contract will be null and void and the applicant will have no payment obligations to the bidder.

 

·       Bidder is expected to provide the lowest corresponding price per E-rate rules.  See https://www.usac.org/e-rate/service-providers/step-2-responding-to-bids/lowest-corresponding-price/ for details.

 

·       Contracts must not prohibit SPIN changes.

 

·       Bidder must agree to provide the Applicant the choice of discount methods (SPI or BEAR).

 

·       Bidder will be automatically disqualified if the District determines that the bidding company has offered any employee of the District any individual gift of more than $20 or gifts totaling more than $50 within a 12 month period. This does not apply to the recent FCC exemptions of the Gift Rule for the COVID pandemic.

 

·       All contracts awarded will be contingent upon E-rate funding and final board approval.  The applicant may choose to do all or part of the project upon funding notification.

 

·       All applicable fees, surcharges, and taxes must be identified on the bid. E-rate rules require the applicants to evaluate the price of eligible goods and services that will be listed on the 471 application during the competitive bidding process. Fees and surcharges that apply but are not listed on the bid will be the responsibility of the bidding company, should their bid be awarded.

 

·       If there is a request for Internal Connections (Category Two) equipment, or Category One equipment listed on this IFCB the applicant will accept bids for functionally equivalent equipment.

 

 

·       DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: The applicant will not accept bids from manufacturers of equipment deemed a national security threat by the Federal Communications Commission. The list of prohibited equipment is available here: https://www.fcc.gov/supplychain/coveredlist. Vendors that submit bids that include these manufacturers will have their bids disqualified.

 

·       DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Vendors must complete and include the C2 Cover Page with their bid. Bids received without the cover page will be disqualified.

·       DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Applicant will not accept bids for refurbished equipment. Any bids containing refurbished equipment will be disqualified.

 

·       DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Service providers are required to bid an entire Project A, Project B , Project C, Project D, Project E, and/or Project F.  Bids for individual components of a single project, or bids that do not include all of the requested items for a single project will be disqualified.

 

·       DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: It will be the bidder’s responsibility to provide documentation about the compatibility requirements listed in this IFCB. Vendors that submit bids without documentation demonstrating the required compatibility listed in this IFCB will have their bids disqualified, unless that vendor has bid the preferred make/model number listed.

 

·       DISQUALIFICATION FACTOR BMIC: Service providers are required to bid an entire Project G and/or Project H.  Bids for individual components of a single project, or bids that do not include all of the requested items for a single project will be disqualified.

 

·       DISQUALIFICATION FACTOR BMIC: Vendors must complete and include the C2 Cover Page with their bid. Bids received without the cover page will be disqualified.

 

·       DISQUALIFICATION FACTOR BMIC: Maintenance bids listing only an hourly rate and not a monthly or annual total will be disqualified.  Vendors quoting an hourly rate are required to also a) confirm that you have the ability/expertise to maintain all of the equipment listed and b) propose a number of hours at a particular rate monthly to properly maintain the entire list of equipment.  Bids that contain only hourly rates, without confirmation that the company can service the list of equipment, or without a monthly total will be disqualified.

 

·        

 


Services and Equipment Requested :

UPDATE 10/29/2025: A PARTS LIST WITH SKU'S HAS BEEN ADDED AS AN ATTACMENT.

INTERNAL CONNECTIONS-Project A- 1-year Licensing.

District needs Installation and configuration of switches and access points. No Drops needed

Type of Equipment

Quantity Vendor Should Bid

Preferred Make/Manufacturer

Antennas, Connectors and Related Components

200

Aruba Compatible Power Supplies for POE Distribution

Switches

100

Aruba 48 port, all POE capable

Antennas, Connectors and Related Components

96

Aruba Compatible DACs

Antennas, Connectors and Related Components

55

Aruba Compatible Optics

Wireless Access Points

800

Indoor Aruba Compatible

 

NOTE: We are requesting WAP and switch  licensing on this IFCB, which sometimes may be categorized as BMIC or MIBS by USAC (the BMIC and MIBS boxes on the 470 have been checked to cover this scenario).

COMPATIBILITY REQUIREMENT:

Must be compatible with existing Aruba Central dashboard.

 

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: The applicant will not accept bids from manufacturers of equipment deemed a national security threat by the Federal Communications Commission. The list of prohibited equipment is available here: https://www.fcc.gov/supplychain/coveredlist. Vendors that submit bids that include these manufacturers will have their bids disqualified.

 

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Vendors must complete and include the C2 Cover Page with their bid. Bids received without the cover page will be disqualified.

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Applicant will not accept bids for refurbished equipment. Any bids containing refurbished equipment will be disqualified.

 

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Service providers are required to bid an entire Project A, Project B , Project C, Project D, Project E, and/or Project F.  Bids for individual components of a single project, or bids that do not include all of the requested items for a single project will be disqualified.

 

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: It will be the bidder’s responsibility to provide documentation about the compatibility requirements listed in this IFCB. Vendors that submit bids without documentation demonstrating the required compatibility listed in this IFCB will have their bids disqualified, unless that vendor has bid the preferred make/model number listed.

 

INTERNAL CONNECTIONS-Project B- 3-year Licensing.

District needs Installation and configuration of switches and access points. No Drops needed

Type of Equipment

Quantity Vendor Should Bid

Preferred Make/Manufacturer

Antennas, Connectors and Related Components

200

Aruba Compatible Power Supplies for POE Distribution

Switches

100

Aruba 48 port, all POE capable

Antennas, Connectors and Related Components

96

Aruba Compatible DACs

Antennas, Connectors and Related Components

55

Aruba Compatible Optics

Wireless Access Points

800

Indoor Aruba Compatible

 

NOTE: We are requesting WAP and switch  licensing on this IFCB, which sometimes may be categorized as BMIC or MIBS by USAC (the BMIC and MIBS boxes on the 470 have been checked to cover this scenario).

COMPATIBILITY REQUIREMENT:

Must be compatible with existing Aruba Central dashboard.

 

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: The applicant will not accept bids from manufacturers of equipment deemed a national security threat by the Federal Communications Commission. The list of prohibited equipment is available here: https://www.fcc.gov/supplychain/coveredlist. Vendors that submit bids that include these manufacturers will have their bids disqualified.

 

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Vendors must complete and include the C2 Cover Page with their bid. Bids received without the cover page will be disqualified.

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Applicant will not accept bids for refurbished equipment. Any bids containing refurbished equipment will be disqualified.

 

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Service providers are required to bid an entire Project A, Project B , Project C, Project D, Project E, and/or Project F.  Bids for individual components of a single project, or bids that do not include all of the requested items for a single project will be disqualified.

 

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: It will be the bidder’s responsibility to provide documentation about the compatibility requirements listed in this IFCB. Vendors that submit bids without documentation demonstrating the required compatibility listed in this IFCB will have their bids disqualified, unless that vendor has bid the preferred make/model number listed.

 

INTERNAL CONNECTIONS-Project C- 5-year Licensing.

District needs Installation and configuration of switches and access points. No Drops needed

Type of Equipment

Quantity Vendor Should Bid

Preferred Make/Manufacturer

Antennas, Connectors and Related Components

200

Aruba Compatible Power Supplies for POE Distribution

Switches

100

Aruba 48 port, all POE capable

Antennas, Connectors and Related Components

96

Aruba Compatible DACs

Antennas, Connectors and Related Components

55

Aruba Compatible Optics

Wireless Access Points

800

Indoor Aruba Compatible

 

NOTE: We are requesting WAP and switch  licensing on this IFCB, which sometimes may be categorized as BMIC or MIBS by USAC (the BMIC and MIBS boxes on the 470 have been checked to cover this scenario).

COMPATIBILITY REQUIREMENT:

Must be compatible with existing Aruba Central dashboard.

 

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: The applicant will not accept bids from manufacturers of equipment deemed a national security threat by the Federal Communications Commission. The list of prohibited equipment is available here: https://www.fcc.gov/supplychain/coveredlist. Vendors that submit bids that include these manufacturers will have their bids disqualified.

 

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Vendors must complete and include the C2 Cover Page with their bid. Bids received without the cover page will be disqualified.

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Applicant will not accept bids for refurbished equipment. Any bids containing refurbished equipment will be disqualified.

 

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Service providers are required to bid an entire Project A, Project B , Project C, Project D, Project E, and/or Project F.  Bids for individual components of a single project, or bids that do not include all of the requested items for a single project will be disqualified.

 

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: It will be the bidder’s responsibility to provide documentation about the compatibility requirements listed in this IFCB. Vendors that submit bids without documentation demonstrating the required compatibility listed in this IFCB will have their bids disqualified, unless that vendor has bid the preferred make/model number listed.

 

INTERNAL CONNECTIONS-Project D- 1-year Licensing.

District needs Installation and configuration of firewalls.

Type of Equipment

Quantity Vendor Should Bid

Preferred Make/Manufacturer

Firewall Service and Components

2

Next Gen FW Fortinet FG3000F or compatible

 

NOTE: We are requesting Firewall  licensing on this IFCB, which sometimes may be categorized as BMIC or MIBS by USAC (the BMIC and MIBS boxes on the 470 have been checked to cover this scenario).

COMPATIBILITY REQUIREMENT:

Must be compatible with existing Aruba Central dashboard.

 

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: The applicant will not accept bids from manufacturers of equipment deemed a national security threat by the Federal Communications Commission. The list of prohibited equipment is available here: https://www.fcc.gov/supplychain/coveredlist. Vendors that submit bids that include these manufacturers will have their bids disqualified.

 

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Vendors must complete and include the C2 Cover Page with their bid. Bids received without the cover page will be disqualified.

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Applicant will not accept bids for refurbished equipment. Any bids containing refurbished equipment will be disqualified.

 

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Service providers are required to bid an entire Project A, Project B , Project C, Project D, Project E, and/or Project F.  Bids for individual components of a single project, or bids that do not include all of the requested items for a single project will be disqualified.

 

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: It will be the bidder’s responsibility to provide documentation about the compatibility requirements listed in this IFCB. Vendors that submit bids without documentation demonstrating the required compatibility listed in this IFCB will have their bids disqualified, unless that vendor has bid the preferred make/model number listed.

 

INTERNAL CONNECTIONS-Project E- 3-year Licensing.

District needs Installation and configuration of firewalls.

Type of Equipment

Quantity Vendor Should Bid

Preferred Make/Manufacturer

Firewall Service and Components

2

Next Gen FW Fortinet FG3000F or compatible

 

NOTE: We are requesting Firewall  licensing on this IFCB, which sometimes may be categorized as BMIC or MIBS by USAC (the BMIC and MIBS boxes on the 470 have been checked to cover this scenario).

COMPATIBILITY REQUIREMENT:

Must be compatible with existing Aruba Central dashboard.

 

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: The applicant will not accept bids from manufacturers of equipment deemed a national security threat by the Federal Communications Commission. The list of prohibited equipment is available here: https://www.fcc.gov/supplychain/coveredlist. Vendors that submit bids that include these manufacturers will have their bids disqualified.

 

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Vendors must complete and include the C2 Cover Page with their bid. Bids received without the cover page will be disqualified.

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Applicant will not accept bids for refurbished equipment. Any bids containing refurbished equipment will be disqualified.

 

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Service providers are required to bid an entire Project A, Project B , Project C, Project D, Project E, and/or Project F.  Bids for individual components of a single project, or bids that do not include all of the requested items for a single project will be disqualified.

 

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: It will be the bidder’s responsibility to provide documentation about the compatibility requirements listed in this IFCB. Vendors that submit bids without documentation demonstrating the required compatibility listed in this IFCB will have their bids disqualified, unless that vendor has bid the preferred make/model number listed.

 

INTERNAL CONNECTIONS-Project F- 5-year Licensing.

District needs Installation and configuration of firewalls.  

Type of Equipment

Quantity Vendor Should Bid

Preferred Make/Manufacturer

Firewall Service and Components

2

Next Gen FW Fortinet FG3000F or compatible

 

NOTE: We are requesting Firewall  licensing on this IFCB, which sometimes may be categorized as BMIC or MIBS by USAC (the BMIC and MIBS boxes on the 470 have been checked to cover this scenario).

COMPATIBILITY REQUIREMENT:

Must be compatible with existing Aruba Central dashboard.

 

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: The applicant will not accept bids from manufacturers of equipment deemed a national security threat by the Federal Communications Commission. The list of prohibited equipment is available here: https://www.fcc.gov/supplychain/coveredlist. Vendors that submit bids that include these manufacturers will have their bids disqualified.

 

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Vendors must complete and include the C2 Cover Page with their bid. Bids received without the cover page will be disqualified.

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Applicant will not accept bids for refurbished equipment. Any bids containing refurbished equipment will be disqualified.

 

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Service providers are required to bid an entire Project A, Project B , Project C, Project D, Project E, and/or Project F.  Bids for individual components of a single project, or bids that do not include all of the requested items for a single project will be disqualified.

 

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: It will be the bidder’s responsibility to provide documentation about the compatibility requirements listed in this IFCB. Vendors that submit bids without documentation demonstrating the required compatibility listed in this IFCB will have their bids disqualified, unless that vendor has bid the preferred make/model number listed.

 

BASIC MAINTENANCE OF INTERNAL CONNECTIONS:

Project G-The District would like a manufacturer’s support contract for these items:

 

Type of Equipment

Quantity Vendor Should Bid

Preferred Make/Manufacturer

Switches

100

Aruba 62xx Switches

Wireless Access Points

800

Aruba 7xx Access Points

 

DISQUALIFICATION FACTOR BMIC: Service providers are required to bid an entire Project G and/or Project H.  Bids for individual components of a single project, or bids that do not include all of the requested items for a single project will be disqualified.

 

DISQUALIFICATION FACTOR BMIC: Vendors must complete and include the C2 Cover Page with their bid. Bids received without the cover page will be disqualified.

 

DISQUALIFICATION FACTOR BMIC: Maintenance bids listing only an hourly rate and not a monthly or annual total will be disqualified.  Vendors quoting an hourly rate are required to also a) confirm that you have the ability/expertise to maintain all of the equipment listed and b) propose a number of hours at a particular rate monthly to properly maintain the entire list of equipment.  Bids that contain only hourly rates, without confirmation that the company can service the list of equipment, or without a monthly total will be disqualified.

 

BASIC MAINTENANCE OF INTERNAL CONNECTIONS:

Project H-The District would like a manufacturer’s support contract for these items:

Type of Equipment

Quantity Vendor Should Bid

Preferred Make/Manufacturer

Firewall Service and Components

2

Fortinet FG3000F

 

DISQUALIFICATION FACTOR BMIC: Service providers are required to bid an entire Project G and/or Project H.  Bids for individual components of a single project, or bids that do not include all of the requested items for a single project will be disqualified.

 

DISQUALIFICATION FACTOR BMIC: Vendors must complete and include the C2 Cover Page with their bid. Bids received without the cover page will be disqualified.

 

DISQUALIFICATION FACTOR BMIC: Maintenance bids listing only an hourly rate and not a monthly or annual total will be disqualified.  Vendors quoting an hourly rate are required to also a) confirm that you have the ability/expertise to maintain all of the equipment listed and b) propose a number of hours at a particular rate monthly to properly maintain the entire list of equipment.  Bids that contain only hourly rates, without confirmation that the company can service the list of equipment, or without a monthly total will be disqualified.

There is an additional document associated with this IFCB. Please click the buttons to download the document.

2026_C2_Bidding_Instructions_92.pdf
Springfirld_C2_COVER_PAGE.pdf
erate_26_parts_list.xlsx

Questions Received with Applicant Answers   ( Ask Questions? )




• Do you require on-site assistance with racking the firewall? • Questions about the existing FortiGate: o How many policies/rules? o How many site-to-site VPNs are required? o How many NAT statements? o How many objects? • Will the two new firewalls be an HA pair?

Answer:

• Do you require on-site assistance with racking the firewall?  

      We would like this optional, and the price quoted.

• Questions about the existing FortiGate:

o How many policies/rules?

      Firewall Policies - 209

      Local In Policies - 42

      IPv4 DoS Policy - 1

      Authentication Rule - 1

o How many site-to-site VPNs are required?

      One is currently active.  We want to plan for growth of up to ten at this time.

o How many NAT statements?

      Policy Based NAT - 171

      Destination VIP NAT - 30

o How many objects?

      Addresses - 456

      ZTNA Tags - 3

      Internet Service Database

            Internet Services - 1,767

      Services - 90

      Schedules - 3

      Virtual IPs - 30

      IP Pools - 117

      Protocol Options - 1

      Traffic Shaping - 5 

• Will the two new firewalls be an HA pair?

      No

For IC Project D,E,F: Is the district looking for the Enterprise or the UTP bundle for the FG3000F firewall?

Answer:

Enterprise

With the switches, how many per building? Need a count per building. With the APs, how many per building? Need a count per building. What is the WAN connectivity back to the firewall between the locations you are putting these new switches and APs? What density are the APs? 2x2, 4x4 or 8x8? What is the uplink on the switches? What is the port speed on the switches? Multigig ports? PoE budget on the switches? What bundle do you want on the Firewall? ATP, UTP, or Enterprise?

Answer:

  1. With the switches, how many per building? Need a count per building.
    1. Study - 13
    2. Wilson's Creek - 13
    3. Cowden - 8
    4. Field - 10
    5. Gray - 12
    6. Harrison - 16
    7. Holland - 6
    8. Jeffries - 10
    9. Mann - 9
  2. With the APs, how many per building? Need a count per building.
    1. Study - 55
    2. Wilson's Creek - 43
    3. Cowden - 28
    4. Field - 42
    5. Gray - 45
    6. Harrison - 40
    7. Jeffries - 47
    8. Mann - 37
    9. Carver - 68
    10. Cherokee - 64
    11. Westport - 79
    12. Hickory Hills - 69
    13. Pleasant View - 55
  1. What is the WAN connectivity back to the firewall between the locations you are putting these new switches and APs?
    1. Our WAN connections are provided by Mediacom and are 10gig
  1. What density are the APs? 2x2, 4x4 or 8x8?
    1. 2x2
  1. What is the uplink on the switches?
    1. At least 10gig
  1. What is the port speed on the switches? Multigig ports?
    1. 9 switches with 48 multigig ports, 4 50G SFP ports
    2. 26 switches with 12 multigig ports, 36 gig ports, 4 10G SFP ports
    3. 30 switches with 48 gig ports, 4 50G SFP ports
    4. 32 switches with 48 gig ports, 4 10G SFP ports
  1. PoE budget on the switches?
    1. 2880W on the 48 mulitgig port switches
    2. 1440W on the rest
  1. What bundle do you want on the Firewall? ATP, UTP, or Enterprise?
    1. Enterprise