All bid deadlines are 11:59pm Pacific Time the date of the bid deadline listed unless otherwise noted.

school Hilldale School District 29
IFCB Posted : Sep 16, 2025
Bid Deadline : Tuesday, Nov 4, 2025

Questions Due By : Thursday, Oct 2, 2025
Applicant Address : Muskogee, OK 74403
IFCB ID : 260001407

IFCB Requirements :

·         Before the listed deadlines, all Questions and Bids must be submitted using the on-line IFCB system. Bids submitted before the bid deadline outside of this system will be disqualified. If the system is down before the deadline, please email your bid to info@crwconsulting.com or fax it to 918.445.0049. Bids or questions submitted in this fashion will be disqualified if the on-line system is active at the time of submission. The applicant reserves the right to request and obtain bids outside of the website system if the bid deadline has passed and zero or one bid is received (the intent for this is to follow USAC guidance on obtaining cost-effective bids).

·        For all requested services and/or products listed on this IFCB: proposals that include generic/encyclopedic price lists will be considered non-responsive and will be disqualified. SPAM and/or robotic responses will not be considered valid bid responses and will be disqualified from consideration.

 

·         Bidder must agree to participate in USF Program (AKA “E-rate”) for the corresponding funding year.

 

·         Please include the correct Service Provider Identification Number (SPIN) on your bid.

 

·         By submitting a bid, bidder certifies that the bidder does have a valid (non-red light status) SPIN for the E-rate program at the time of submission. Should the Applicant discover that the bidder is on red light status, or if the FCC classifies the bidder as on red-light status before work is performed and invoices are paid, the contract will be null and void and the applicant will have no payment obligations to the bidder.

 

·         Bidder is expected to provide the lowest corresponding price per E-rate rules.  See https://www.usac.org/e-rate/service-providers/step-2-responding-to-bids/lowest-corresponding-price/ for details.

 

·         Contracts must not prohibit SPIN changes.

 

·         Bidder must agree to provide the Applicant the choice of discount methods (SPI or BEAR).

 

·         Bidder will be automatically disqualified if the District determines that the bidding company has offered any employee of the District any individual gift of more than $20 or gifts totaling more than $50 within a 12 month period. This does not apply to the recent FCC exemptions of the Gift Rule for the COVID pandemic.

 

·         All contracts awarded will be contingent upon E-rate funding and final board approval.  The applicant may choose to do all or part of the project upon funding notification.

 

·         All applicable fees, surcharges, and taxes must be identified on the bid. E-rate rules require the applicants to evaluate the price of eligible goods and services that will be listed on the 471 application during the competitive bidding process. Fees and surcharges that apply but are not listed on the bid will be the responsibility of the bidding company, should their bid be awarded.

 

·         If there is a request for Internal Connections (Category Two) equipment, or Category One equipment listed on this IFCB the applicant will accept bids for functionally equivalent equipment.

 

·         E-rate rules require applicants to evaluate the cost of eligible goods and services, and to cost-allocate out the amount for ineligible services from their funding request. If your company will be bidding internet access service, please identify the amount to be cost-allocated out for the ineligible services – email service, web hosting, content filtering, or other bundled ineligible services.

·         INTERNET ACCESS DISQUALIFICATION FACTOR: Bids submitted for services to an incorrect address will be disqualified.

 

·         INTERNET ACCESS DISQUALIFICATION FACTOR: Your bid must identify the bandwidth you are proposing and associated price or your bid will be disqualified.

 

·         INTERNET ACCESS DISQUALIFICATION FACTOR: Any and all installation charges must be identified on your bid. If you submit a bid indicating that installation charges may apply without listing those charges, we will consider your bid incomplete and disqualify your bid.

 

·         INTERNET ACCESS DISQUALIFICATION FACTOR: Bidders who are not eligible to provide OUSF support will be disqualified. By placing a bid for these services, the bidder agrees to file the completed OUSF affidavit within 90 days of the start of service (applicant agrees to complete their portion in a timely fashion after the request for completion by the winning bidder).

·         LEASED LIT FIBER DISQUALIFICATION FACTOR: Bidders who are not eligible to provide OUSF support will be disqualified. By placing a bid for these services, the bidder agrees to file the completed OUSF affidavit within 90 days of the start of service (applicant agrees to complete their portion in a timely fashion after the request for completion by the winning bidder).

 

·         LEASED LIT FIBER DISQUALIFICATION FACTOR: Bids submitted for services to an incorrect address will be disqualified.

 

·         LEASED LIT FIBER DISQUALIFICATION FACTOR: Any and all installation charges must be identified on your bid. If you submit a bid indicating that installation charges may apply without listing those charges, we will consider your bid incomplete and disqualify your bid.

·         DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: The applicant will not accept bids from manufacturers of equipment deemed a national security threat by the Federal Communications Commission. The list of prohibited equipment is available here: https://www.fcc.gov/supplychain/coveredlist . Vendors that submit bids that includes these manufacturers will have their bid disqualified.

 

·         DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Vendors must complete and include the C2 Cover Page with their bid. Bids received without the cover page will be disqualified.

·         DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Service providers are required to bid the entire hardware project.  Bids for individual components, or bids that do not include all of the requested items for the project will be disqualified.

 

·         DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Applicant will not accept bids for refurbished equipment. Any bids containing refurbished equipment will be disqualified.


Services and Equipment Requested :

UPDATE 10/7/25 - THE BID DEADLINE HAS BEEN UPDATED TO 11/04/25.

Category One:

Internet Access - District currently has 5 GB bandwidth and would like to increase to 10 GB. The terminating address for this circuit is located at the High School - 300 East Smith Ferry Rd, Muskogee, OK 74403. Bids should include pricing for 5 GB and 10GB, based on a 5-year term. Bids should also include a leased router.

 

E-rate rules require applicants to evaluate the cost of eligible goods and services, and to cost-allocate out the amount for ineligible services from their funding request. If your company will be bidding internet access service, please identify the amount to be cost-allocated out for the ineligible services – email service, web hosting, content filtering, or other bundled ineligible services.


NOTE: Applicant will accept any technologies bid. It is our intention to meet all OUSF Fair and Open Competitive Bidding requirements. If you are a NECA/tariffed company, bids for your tariffed rates are allowed. If any of the specified bandwidth speeds are not a tariffed/NECA rate, please bid the closest rate you have available, within the limits of the bandwidth range specified on the 470.

 

INTERNET ACCESS DISQUALIFICATION FACTOR: Bids submitted for services to an incorrect address will be disqualified.

 

INTERNET ACCESS DISQUALIFICATION FACTOR: Your bid must identify the bandwidth you are proposing and associated price or your bid will be disqualified.

 

INTERNET ACCESS DISQUALIFICATION FACTOR: Any and all installation charges must be identified on your bid. If you submit a bid indicating that installation charges may apply without listing those charges, we will consider your bid incomplete and disqualify your bid.

 

INTERNET ACCESS DISQUALIFICATION FACTOR: Bidders who are not eligible to provide OUSF support will be disqualified. By placing a bid for these services, the bidder agrees to file the completed OUSF affidavit within 90 days of the start of service (applicant agrees to complete their portion in a timely fashion after the request for completion by the winning bidder).

 

Leased Lit Fiber – The district currently has 10 GB leased lit fiber from the High School –300 East Smith Ferry Rd, Muskogee, OK 74403 to the Elementary School – 315 East Peak Blvd, Muskogee, OK 74403. Vendors should bid 10 GB through 40 GB. Bids should include optional leased switches.

 

NOTE: Applicant will accept any technologies bid. It is our intention to meet all OUSF Fair and Open Competitive Bidding requirements. If you are a NECA/tariffed company, bids for your tariffed rates are allowed. If any of the specified bandwidth speeds are not a tariffed/NECA rate, please bid the closest rate you have available, within the limits of the bandwidth range specified on the 470.

 

LEASED LIT FIBER DISQUALIFICATION FACTOR: Bidders who are not eligible to provide OUSF support will be disqualified. By placing a bid for these services, the bidder agrees to file the completed OUSF affidavit within 90 days of the start of service (applicant agrees to complete their portion in a timely fashion after the request for completion by the winning bidder).

 

LEASED LIT FIBER DISQUALIFICATION FACTOR: Bids submitted for services to an incorrect address will be disqualified.

 

LEASED LIT FIBER DISQUALIFICATION FACTOR: Any and all installation charges must be identified on your bid. If you submit a bid indicating that installation charges may apply without listing those charges, we will consider your bid incomplete and disqualify your bid.

 

Category Two:

VOLUNTARY SITE VISIT

Vendors wishing to bid on internal connections can attend a voluntary site visit on October 1st, 2025 at 9:00am. Vendors will meet at 300 East Smith Ferry Road, Muskogee, OK 74403. Vendors will check in with Anna McFarland.

 

INTERNAL CONNECTIONS

Full installation for every IDF/MDF as well as testing of all devices.

 

Type of Equipment

Quantity Vendor Should Bid

 

Preferred Make/Manufacturer

UPS/Battery Backup

50

APC SMT1500 RM 2U. Run time 30-40 minutes

 

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: The applicant will not accept bids from manufacturers of equipment deemed a national security threat by the Federal Communications Commission. The list of prohibited equipment is available here: https://www.fcc.gov/supplychain/coveredlist . Vendors that submit bids that includes these manufacturers will have their bid disqualified.

 

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Vendors must complete and include the C2 Cover Page with their bid. Bids received without the cover page will be disqualified.

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Service providers are required to bid the entire hardware project.  Bids for individual components, or bids that do not include all of the requested items for the project will be disqualified.

 

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Applicant will not accept bids for refurbished equipment. Any bids containing refurbished equipment will be disqualified.

 

 


There is an additional document associated with this IFCB. Please click the buttons to download the document.

2026_C2_Bidding_Instructions_18.pdf
HILLDALE_C2_COVER_PAGE3.pdf

Questions Received with Applicant Answers   ( Ask Questions? )




Wanted to check on the accuracy of the quantity of 50 UPS units needed.

Answer:

Yes, it is 50 for the entire district.  

Will all UPS’s be installed l in the same school, across a campus? If multiple schools, can you list them out with locations. How are we doing disposal? Will the vendor be responsible or with the district handle disposal? Do you have an estimated time that install will be expected assuming USAC approvals and equipment delivery? Will there be a staging area? Access , will we need to be escorted?

Answer:

  No, All ups battery will not be installed in the same location.  These will need to be installed @ every IDF/MDF at the:

 

HS - 300 East Smith Ferry Rd. Muskogee, Ok 74403

    MDF - HS Rm. Alt. Ed   =  1 UPS

    IDF 1- HS Robotics         = 2 UPS

    IDF 2- HS Rm 60        = 1 UPS

          IDF 3 - HS IT Office         = 1 UPS

          IDF 4 - HS SRO Office    = 2 UPS

          IDF 5 - HS Band Rm        = 1 UPS

    IDF 6- HS Cafe Office     = 1 UPS

        Football Field House - Behind HS   = 1 UPS

        Soccer Field House - Behind HS      = 1 UPS

        Baseball/Softball Field House - Behind HS  = 1 UPS

 

MS - 400 East Smith Ferry Rd. Muskogee, Ok 74403

    IDF 7- MS Rm 20        = 1 UPS

    IDF 8 - MS Rm 6          = 3 UPS

 

IT/Maint./Trans. - 500 East Smith Ferry Rd. Muskogee, Ok 74403     = 1 UPS

 

Admin. Bldg. - 315 East Peak Blvd. Muskogee, Ok 74403     = 1 UPS

 

Elem. - 313 East Peak Blvd. Muskogee, Ok 74403

    MDF - Across from Library         = 4 UPS

    IDF 1 - US Small Office                         = 1 UPS

          IDF 2 - UE RM  75                                       = 2 UPS

    IDF 3 - Elem. Library                                = 2 UPS

    IDF 4 - Elme Computer Lab                  = 1 UPS

    IDF 5 - RM 60                                               = 1 UPS

    IDF 6 - Lower Elem. Tchr. Lounge      = 3 UPS

    IDF 7 - Lower Elem. Paper Rm.           = 2 UPS

    IDF 8 - Elem Cafe Office             = 1 UPS

    IDF 9 - Elem 5th Grade Hall/Rack 1   =  1 UPS

                            Rack 2  =  1 UPS

 

Disposal of old UPS batteries will need to be completed by the company who does installation as well.

    No, This will need to be contracted by the bidder.  We do not have a way to dispose of said UPS batteries.

Install - June or July of 2026, assuming we have our funding letter by that time

 

Yes, There will be a staging area, this will need to be in the Elem IDF 9 location in the 5th grade IDF.

No, we will provide an access key fob when company arrives, be sure to check in with the IT Dept. Director Anna McFarland.

For the MDF’s, what size of UPS’s are you needing, and what kind of run time do you need? I see in the bid that you listed the units you currently have. Are you needing upgraded units from that with longer run times, or do those units satisfy the IDF closets?

Answer:

Size of UPS will need to be 1500 and at least 30 min. Backup time for the IDF's.   For the Cabinets in the MDF the UPS Batteries will need to be Model 5000 and will need to have a run time of minimum 1 hr.  

--Are you wanting to replace the 2 5000 UPS units in the 2 HS MDF racks? --The remaining units will be 1500s?

Answer:
Yes, we would like to replace both of the UPS units, on one cabinet and one on the second cabinet next to the 1st.  There are 3 5000 UPS batteries in the MDF.