All bid deadlines are 11:59pm Pacific Time the date of the bid deadline listed unless otherwise noted.

school Calera School District 48
IFCB Posted : Dec 15, 2023
Bid Deadline : Friday, Jan 12, 2024

Questions Due By : Thursday, Dec 21, 2023
Applicant Address : Calera, OK 74730
IFCB ID : 240008924

IFCB Requirements :

·         Before the listed deadlines, all Questions and Bids must be submitted using the on-line IFCB system. Bids submitted before the bid deadline outside of this system will be disqualified. If for some reason the system is down before the respective deadline, please email your bid to info@crwconsulting.com or fax it to 918.445.0049. Bids or questions submitted in this fashion will be disqualified if the on-line system is active at the time of submission.

·         For all requested services and/or products listed on this IFCB: proposals that include generic/encyclopedic price lists will be considered non-responsive and will be disqualified.

 

·         Bidder must agree to participate in USF Program (AKA “E-Rate”) for the corresponding funding year.

 

·         Please include the correct Service Provider Identification Number (SPIN) on your bid.

 

·         By submitting a bid, bidder certifies that the bidder does have a valid (non-red light status) SPIN for the E-Rate program at the time of submission. Should the Applicant discover that the bidder is on red light status, or if the FCC classifies the bidder as on red-light status before work is performed and invoices are paid, the contract will be null and void and the applicant will have no payment obligations to the bidder.

 

·         Bidder is expected to provide the lowest corresponding price per E-Rate rules.  See https://www.usac.org/e-rate/service-providers/step-2-responding-to-bids/lowest-corresponding-price/ for details.

 

·         Contracts must not prohibit SPIN changes.

 

·         Bidder must agree to provide the Applicant the choice of discount methods (SPI or BEAR).

 

·         Bidder will be automatically disqualified if the District determines that the bidding company has offered any employee of the District any individual gift of more than $20 or gifts totaling more than $50 within a 12 month period. This does not apply to the recent FCC exemptions of the Gift Rule for the COVID pandemic.

 

·         All contracts awarded will be contingent upon E-Rate funding and final board approval.  The applicant may choose to do all or part of the project upon funding notification.

 

·         All applicable fees, surcharges, and taxes must be identified on the bid. E-Rate rules require the applicants to evaluate the price of eligible goods and services that will be listed on the 471 application during the competitive bidding process. Fees and surcharges that apply but are not listed on the bid will be the responsibility of the bidding company, should their bid be awarded.

 

·         If there is a request for Internal Connections (Category Two) equipment, or Category One equipment listed on this IFCB the applicant will accept bids for functionally equivalent equipment.

 

 

·         LEASED LIT FIBER DISQUALIFICATION FACTOR: Bidders who are not eligible to provide OUSF support will be disqualified. By placing a bid for these services, the bidder agrees to file the completed OUSF affidavit within 90 days of the start of service (applicant agrees to complete their portion in a timely fashion after the request for completion by the winning bidder).

 

·         LEASED LIT FIBER DISQUALIFICATION FACTOR: Bids submitted for services to an incorrect address will be disqualified.

 

·         LEASED LIT FIBER DISQUALIFICATION FACTOR: Any and all installation charges must be identified on your bid. If you submit a bid indicating that installation charges may apply without listing those charges, we will consider your bid incomplete and disqualify your bid.

 

·         LEASED LIT FIBER DISQUALIFICATION FACTOR: Vendors must bid all connections. If vendors submit a bid missing any connection, we will consider your bid incomplete and disqualify your bid.

 

·         The winning vendor will be required to complete the USAC approved Item 21 template for the project within 7 working days after notification that the vendor has won the bid.

 

·         DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: The applicant will not accept bids from manufacturers of equipment deemed a national security threat by the Federal Communications Commission. The list of prohibited equipment is available here: https://www.fcc.gov/supplychain/coveredlist. Vendors that submit bids that include these manufacturers will have their bids disqualified.

 

·         DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Vendors must complete and include the C2 Cover Page with their bid. Bids received without the cover page will be disqualified.

 

·         DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Service providers are required to bid the entire hardware project.  Bids for individual components of the project will be disqualified.

 

·         DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: It will be the bidder’s responsibility to provide documentation about the compatibility requirements listed in this IFCB. Vendors that submit bids without documentation demonstrating the required compatibility listed in this IFCB will have their bids disqualified, unless that vendor has bid the preferred make/model number listed.

 

·         DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Applicant will not accept bids for refurbished equipment. Any bids containing refurbished equipment will be disqualified.

 

·         DISQUALIFICATION FACTOR BMIC: Service providers are required to bid the entire maintenance project.  Bids for individual components of the project will be disqualified.

 

·         DISQUALIFICATION FACTOR BMIC: Vendors must complete and include the C2 Cover Page with their bid. Bids received without the cover page will be disqualified.

 

·         DISQUALIFICATION FACTOR BMIC: Maintenance bids listing only an hourly rate and not a monthly or annual total will be disqualified.  Vendors quoting an hourly rate are required to also a) confirm that you have the ability/expertise to maintain all of the equipment listed and b) propose a number of hours at a particular rate monthly to properly maintain the entire list of equipment.  Bids that contain only hourly rates, without confirmation that the company can service the list of equipment, or without a monthly total will be disqualified.

 

·         DISQUALIFICATION FACTOR MIBS: Vendors must complete and include the C2 Cover Page with their bid. Bids received without the cover page will be disqualified.

 

·         DISQUALIFICATION FACTOR MIBS: Service providers are required to bid the entire project.  Bids for individual components of the project will be disqualified.


Services and Equipment Requested :

Category One:

Leased Lit Fiber- 3 circuits. The applicant requests bids for bandwidth ranges of 10 Gbps to 25 Gbps. Applicant requests five-year contract terms.

Hub – 209 N 3rd St, Calera, OK 74730

1.       407 Rose Hill Lane, Calera, OK 74730

2.       312 W Smiser, Calera, OK 74730

3.       401 W Smiser, Calera, OK 74730

LEASED LIT FIBER DISQUALIFICATION FACTOR: Bidders who are not eligible to provide OUSF support will be disqualified. By placing a bid for these services, the bidder agrees to file the completed OUSF affidavit within 90 days of the start of service (applicant agrees to complete their portion in a timely fashion after the request for completion by the winning bidder).

 

LEASED LIT FIBER DISQUALIFICATION FACTOR: Bids submitted for services to an incorrect address will be disqualified.

 

LEASED LIT FIBER DISQUALIFICATION FACTOR: Any and all installation charges must be identified on your bid. If you submit a bid indicating that installation charges may apply without listing those charges, we will consider your bid incomplete and disqualify your bid.

 

LEASED LIT FIBER DISQUALIFICATION FACTOR: Vendors must bid all connections. If vendors submit a bid missing any connection, we will consider your bid incomplete and disqualify your bid.

 

Category Two:

INTERNAL CONNECTIONS

New building internal connections. Please include installation & configuration for all devices and provide bids with turnkey solutions.

 

 

Type of Equipment

Quantity Vendor Should Bid

 

Preferred Make/Manufacturer

Racks

1

EWMS362436 Hoffman

Switches

7

UNIFI USW-PRO-R8-POE

Switches

1

USW-PRO-24-POE

Antennas, Connectors & Related Components

2

UACC-OM-SM-10G-D-2

UPS/Battery Backup

1

CyberPower CP1500PFCRM2U PFC Sinewave UPS Systems

Wireless Access Points

33

Unifi U6-pro

Wireless Controller

1

Official UniFi Hosting

Cabling

216

CAT6

Cabling

216

UNIFI UC-Patch-RJ45

Antennas, Connectors & Related Components

9

UACC-Rack-Panel-Patch-Blank-24

Antennas, Connectors & Related Components

216

Keystones

 

NOTE: We are requesting WAP, controller, and switch licenses on this IFCB, which sometimes may be categorized as BMIC or MIBS by USAC (the BMIC and MIBS boxes on the 470 have been checked to cover this scenario).

COMPATIBILITY REQUIREMENT:

All equipment must be compatible with existing Official Unifi Hosting.

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: The applicant will not accept bids from manufacturers of equipment deemed a national security threat by the Federal Communications Commission. The list of prohibited equipment is available here: https://www.fcc.gov/supplychain/coveredlist. Vendors that submit bids that include these manufacturers will have their bids disqualified.

 

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Vendors must complete and include the C2 Cover Page with their bid. Bids received without the cover page will be disqualified.

 

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Service providers are required to bid the entire hardware project.  Bids for individual components of the project will be disqualified.

 

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: It will be the bidder’s responsibility to provide documentation about the compatibility requirements listed in this IFCB. Vendors that submit bids without documentation demonstrating the required compatibility listed in this IFCB will have their bids disqualified, unless that vendor has bid the preferred make/model number listed.

 

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Applicant will not accept bids for refurbished equipment. Any bids containing refurbished equipment will be disqualified.

 

BASIC MAINTENANCE OF INTERNAL CONNECTIONS:

School BMIC—The district would like a block of 20 hours per month for the support of eligible equipment.

Type of Equipment

Quantity Vendor Should Bid

 

Preferred Make/Manufacturer

Firewall Service & Components

1

Netgate Super Micro 1537

Switches

2

US 16 XG

Switches

1

US 24 250W

Switches

13

US 48 750W

Switches

5

US 48 G1

Switches

2

US L2 48 PoE

Switches

4

USW Pro 48

Switches

2

USW Pro 48 PoE

Wireless Access Points

2

UAP AC HD

Wireless Access Points

57

UAP AC Pro

Wireless Access Points

23

UAP Pro

Wireless Controller

1

Official unifi hosting

 

DISQUALIFICATION FACTOR BMIC: Service providers are required to bid the entire maintenance project.  Bids for individual components of the project will be disqualified.

 

DISQUALIFICATION FACTOR BMIC: Vendors must complete and include the C2 Cover Page with their bid. Bids received without the cover page will be disqualified.

 

DISQUALIFICATION FACTOR BMIC: Maintenance bids listing only an hourly rate and not a monthly or annual total will be disqualified.  Vendors quoting an hourly rate are required to also a) confirm that you have the ability/expertise to maintain all of the equipment listed and b) propose a number of hours at a particular rate monthly to properly maintain the entire list of equipment.  Bids that contain only hourly rates, without confirmation that the company can service the list of equipment, or without a monthly total will be disqualified.

 

Managed Internal Broadband Service (MIBS):

The district would like MIBS services for the following existing equipment.

Type of Equipment

Quantity Vendor Should Bid

 

Preferred Make/Manufacturer

Firewall Service & Components

1

Netgate Super Micro 1537

Switches

2

US 16 XG

Switches

1

US 24 250W

Switches

13

US 48 750W

Switches

5

US 48 G1

Switches

2

US L2 48 PoE

Switches

4

USW Pro 48

Switches

2

USW Pro 48 PoE

Wireless Access Points

2

UAP AC HD

Wireless Access Points

57

UAP AC Pro

Wireless Access Points

23

UAP Pro

Wireless Controller

1

Official unifi hosting

 

DISQUALIFICATION FACTOR MIBS: Vendors must complete and include the C2 Cover Page with their bid. Bids received without the cover page will be disqualified.

 

DISQUALIFICATION FACTOR MIBS: Service providers are required to bid the entire project.  Bids for individual components of the project will be disqualified.


There is an additional document associated with this IFCB. Please click the buttons to download the document.

CALERA_C2_COVER_PAGE2.pdf

Questions Received with Applicant Answers   ( Ask Questions? )