All bid deadlines are 11:59pm Pacific Time the date of the bid deadline listed unless otherwise noted.

school Perth Amboy School District
IFCB Posted : Oct 14, 2022
Bid Deadline : Friday, Nov 25, 2022

Questions Due By : Friday, Oct 28, 2022
Applicant Address : Perth Amboy, NJ 08861
IFCB ID : 230002468

IFCB Requirements :

·         All Questions and Bids must be submitted using the on-line IFCB system. If for some reason the system is down before the respective deadline, please email your bid to info@crwconsulting.com or fax it to 918.445.0049. Bids or questions submitted in this fashion will be disqualified if the on-line system is active at the time of submission.

 

·         Bidder must agree to participate in USF Program (AKA “E-rate”) for the corresponding funding year.

 

·         Please include the correct Service Provider Identification Number (SPIN) on your bid.

 

·         By submitting a bid, bidder certifies that the bidder does have a valid (non-red light status) SPIN for the E-rate program at the time of submission. Should the Applicant discover that the bidder is on red light status, or if the FCC classifies the bidder as on red-light status before work is performed and invoices are paid, the contract will be null and void and the applicant will have no payment obligations to the bidder.

 

·         Bidder is expected to provide the lowest corresponding price per E-rate rules.  See https://www.usac.org/e-rate/service-providers/step-2-responding-to-bids/lowest-corresponding-price/ for details.

 

·         Contracts must not prohibit SPIN changes.

 

·         Bidder must agree to provide the Applicant the choice of discount methods (SPI or BEAR).

 

·         Bidder will be automatically disqualified if the District determines that the bidding company has offered any employee of the District any individual gift of more than $20 or gifts totaling more than $50 within a 12 month period. This does not apply to the recent FCC exemptions of the Gift Rule for the COVID pandemic.

 

·         All contracts awarded will be contingent upon E-rate funding and final board approval.  The applicant may choose to do all or part of the project upon funding notification.

 

·         All contracts awarded under this IFCB bidding process may be voluntarily renewed by the applicant, upon written notice to the provider, for five consecutive one year terms. Please include this language in your final contract.

 

·         All applicable fees, surcharges, and taxes must be identified on the bid. E-rate rules require the applicants to evaluate the price of eligible goods and services that will be listed on the 471 application during the competitive bidding process. Fees and surcharges that apply but are not listed on the bid will be the responsibility of the bidding company, should their bid be awarded.

 

·         If the applicant is requesting purchases of new equipment, or maintenance of that new equipment, bids for functionally equivalent equipment will be accepted.

 

·         The winning vendor will be required to complete the USAC approved Item 21 template for the project within 7 working days after notification that the vendor has won the bid.

·         DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: The applicant will not accept bids from manufacturers of equipment deemed a national security threat by the Federal Communications Commission. The list of prohibited equipment is available here: https://www.fcc.gov/supplychain/coveredlist . Vendors that submit bids that includes these manufacturers will have their bid disqualified.

 

·         DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Vendors must complete and include the C2 Cover Page with their bid. Bids received without the cover page will be disqualified.

·         DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Winning vendor will be required to get a performance bond of $1,000,000 or their bid will be disqualified.

 

·         DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Service providers are required to bid the entire hardware project.  Bids for individual components of the project will be disqualified.

·         DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: It will be the bidder’s responsibility to provide documentation about the compatibility requirements listed in this IFCB. Vendors that submit bids without documentation demonstrating the required compatibility listed in this IFCB will have their bids disqualified, unless that vendor has bid the preferred make/model number listed.

·         DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Applicant will not accept bids for refurbished equipment. Any bids containing refurbished equipment will be disqualified.

·         DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Bids that include equipment that was manufactured for use outside of the United States will be disqualified.

·         DISQUALIFICATION FACTOR BMIC: Service providers are required to bid the entire maintenance project.  Bids for individual components of the project will be disqualified.

·         DISQUALIFICATION FACTOR BMIC: Vendors must complete and include the C2 Cover Page with their bid. Bids received without the cover page will be disqualified.

·         DISQUALIFICATION FACTOR BMIC: Maintenance bids listing only an hourly rate and not a monthly or annual total will be disqualified.  Vendors quoting an hourly rate are required to also a) confirm that you have the ability/expertise to maintain all of the equipment listed and b) propose a number of hours at a particular rate monthly to properly maintain the entire list of equipment.  Bids that contain only hourly rates, without confirmation that the company can service the list of equipment, or without a monthly total will be disqualified.


Services and Equipment Requested :

UPDATE 10/18/2022 - The questions deadline has been updated to 10/28/2022. A voluntary site visit for Internal Connections will be held on 10/25/2022 at 9am. Vendors will meet at Perth Amboy HS, 300 Eagle Ave, Perth Amboy, NJ 08861. Vendors will check in with Roman Rodriguez. 

NOTE: 470/IFCB# 230002468 REPLACED THE INTERNAL CONNECTIONS SECTION ON 470/IFCB# 230001056.

Category Two:

 

VOLUNTARY SITE VISIT

 

Vendors wishing to bid on internal connections can attend a voluntary site visit on October 25th, 2022, at 9am. Vendors will meet at Perth Amboy High School, 300 Eagle Ave, Perth Amboy, NJ 08861. Vendors will check in with Roman Rodriguez. 

 

INTERNAL CONNECTIONS

The district will be replacing all end-of-life switches. Bids should include installation, activation or initial configuration.

 

Type of Equipment

Quantity Vendor Should Bid

 

Preferred Make/Manufacturer

Antennas, Connectors, and related components

440

Extreme Networks

Power Cord, 15A, USA, NEMA 5-15, IEC320-C15. Part Number 10099

Antennas, Connectors, and related components

376

Extreme Networks 1100-Watt AC PoE Power Supply Module - Front to Back airflow. Part Number XN-ACPWR-1100W-FB

Antennas, Connectors, and related components

64

Extreme Networks 350-Watt AC Power Supply Module - Front to Back airflow. Part Number

XN-ACPWR-350W-FB

Cabling

123

Extreme Networks 100G PASSIVE DAC QSFP28 0.5M MSA EQPT1H8FR1FCL100. Part Number  

100G-DACP-QSFPZ5M

Cabling

26

Extreme Networks 100G, Passive DAC, QSFP28, 1m, MSA P/N: EQPC1HPC010C0100. Part Number 100G-DACP-QSFP1M

Cabling

4

Extreme Networks 100G, Passive DAC, QSFP28, 3m, MSA P/N: EQPC1HPC030C0100. Part Number 100G-DACP-QSFP3M

Modules, GBIC and transceivers

188

Extreme Networks 5520 Versatile Interface Module with four 10GbE SFP+ ports LRM MACsec capable supported on ExtremeSwitching 5520.

Part Number 5520-VIM-4XE

Switch

188

Extreme Networks - ExtremeSwitching 5520 12 100Mb/1Gb/2.5Gb/5Gb 802.3bt 90W PoE 36 10/100/1000BASET FDX/HDX 802.3bt 90W PoE  2 stacking/QSFP28 1 unpopulated VIM slot MACsec capable 3 fan modules 2 unpopulated modular PSU slots. Includes 1-year XIQ Pilot Cloud subscription. Part Number

5520-12MW-36W

Switch

32

Extreme Networks - ExtremeSwitching X465 with 24 1/10Gb SFP+ LRM and MACSEC capable ports includes fan modules, EXOS Advanced Edge, 1 VIM5 slot, 2 PSU slots, rack mount kit. Part Number X465-24XE

 

NOTE: We are requesting switch licenses on this IFCB, which sometimes may be categorized as BMIC or MIBS by USAC (the BMIC and MIBS boxes on the 470 have been checked to cover this scenario).

 

COMPATIBILITY REQUIREMENT:

Equipment must be compatible with existing Extreme equipment.

 

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: The applicant will not accept bids from manufacturers of equipment deemed a national security threat by the Federal Communications Commission. The list of prohibited equipment is available here: https://www.fcc.gov/supplychain/coveredlist . Vendors that submit bids that includes these manufacturers will have their bid disqualified.

 

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Vendors must complete and include the C2 Cover Page with their bid. Bids received without the cover page will be disqualified.

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Winning vendor will be required to get a performance bond of $1,000,000 or their bid will be disqualified.

 

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Service providers are required to bid the entire hardware project.  Bids for individual components of the project will be disqualified.

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: It will be the bidder’s responsibility to provide documentation about the compatibility requirements listed in this IFCB. Vendors that submit bids without documentation demonstrating the required compatibility listed in this IFCB will have their bids disqualified, unless that vendor has bid the preferred make/model number listed.

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Applicant will not accept bids for refurbished equipment. Any bids containing refurbished equipment will be disqualified.

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Bids that include equipment that was manufactured for use outside of the United States will be disqualified.

 

 

BASIC MAINTENANCE OF INTERNAL CONNECTIONS:

The district would like a manufacturer’s support contract for these items

 

Type of Equipment

Quantity Vendor Should Bid

 

Preferred Make/Manufacturer

Switches

188

Extreme Networks EW NBD AHR 5520-12MW-36W. Part Number 97004-5520-12MW-36W

Modules, GBIC and Transceivers

188

Extreme Networks EW NBD AHR 5520-VIM-4XE. Part Number 97004-5520-VIM-4XE

Switches

32

Extreme Networks EW NBD AHR X465-24XE. Part Number 97004-X465-24XE

 

DISQUALIFICATION FACTOR BMIC: Service providers are required to bid the entire maintenance project.  Bids for individual components of the project will be disqualified.

DISQUALIFICATION FACTOR BMIC: Vendors must complete and include the C2 Cover Page with their bid. Bids received without the cover page will be disqualified.

DISQUALIFICATION FACTOR BMIC: Maintenance bids listing only an hourly rate and not a monthly or annual total will be disqualified.  Vendors quoting an hourly rate are required to also a) confirm that you have the ability/expertise to maintain all of the equipment listed and b) propose a number of hours at a particular rate monthly to properly maintain the entire list of equipment.  Bids that contain only hourly rates, without confirmation that the company can service the list of equipment, or without a monthly total will be disqualified.

 


There is an additional document associated with this IFCB. Please click the buttons to download the document.

2023_C2_Bidding_Instructions77.docx
PERTH_AMBOY_C2_COVER_PAGE3.pdf

Questions Received with Applicant Answers   ( Ask Questions? )




I am the E-Rate Project Coordinator. We are interested in the project on Form 470 Application Number 230002468 for Perth Amboy School District. Will you and/or the team at the district be holding a walk-through for this project? I look forward to hearing from you soon. Thank you,

Answer:

VOLUNTARY SITE VISIT

 

Vendors wishing to bid on internal connections can attend a voluntary site visit on October 25th, 2022, at 9am. Vendors will meet at Perth Amboy High School, 300 Eagle Ave, Perth Amboy, NJ 08861. Vendors will check in with Roman Rodriguez. 

Do you have network diagrams/Visios that can be shared? If not, do you have a switch breakdown per closet? What are the current switches in the environment today? Is there a L3 core at each school? What WAN connectivity or circuits do you have between buildings? Do you utilize any NAC solutions like ISE, ClearPass, etc.? Is this rip and replace or will there be a redesign? What type of fiber is between the closets? Is it 10gb? Redundant connections? Do you have the SFPs accounted for since they aren’t on the 470? What’s are the depths of the cabinets/racks (many new switches today are longer)?

Answer:

Do you have network diagrams/Visios that can be shared? We will provide those to the winning bidder.  

What are the current switches in the environment today? Extreme Networks 670 Aggregation, Extreme Networks 460 EDGE Access.

Is there a L3 core at each school? CORE is only in the main campus.

What WAN connectivity or circuits do you have between buildings? District owned fiber.

Do you utilize any NAC solutions like ISE, ClearPass, etc.? We utilize Extreme Network Management as our NAC solution.

Is this rip and replace or will there be a redesign? Rip and Replace

What type of fiber is between the closets? Single Mode

Is it 10gb? Yes

Redundant connections? Yes, with TOP and BOTTOM CORE

Do you have the SFPs accounted for since they aren’t on the 470? They were added to the 470

2.0

100G-DACP-QSFPZ5M

100G PASSIVE DAC QSFP28 0.5M MSA EQPT1H8FR1FCL100

Extreme Networks

123

3.0

100G-DACP-QSFP1M

100G, Passive DAC, QSFP28, 1m, MSA P/N: EQPC1HPC010C0100.

Extreme Networks

26

4.0

100G-DACP-QSFP3M

100G, Passive DAC, QSFP28, 3m, MSA P/N: EQPC1HPC030C0100.

Extreme Networks

4

I submitted several questions but do not see the responses. Here they are again in case you did not receive them. Do you have network diagrams/Visios that can be shared? If not, do you have a switch breakdown per closet? What are the current switches in the environment today? Is there a L3 core at each school? What WAN connectivity or circuits do you have between buildings? Do you utilize any NAC solutions like ISE, ClearPass, etc.? Is this rip and replace or will there be a redesign? What type of fiber is between the closets? Is it 10gb? Redundant connections? Do you have the SFPs accounted for since they aren’t on the 470? What’s are the depths of the cabinets/racks (many new switches today are longer)?

Answer:
The questions have been answered. It may take several days for the school to gather the information to provide answers to questions.