All bid deadlines are 11:59pm Pacific Time the date of the bid deadline listed unless otherwise noted.
· All Questions and Bids must be submitted using the on-line IFCB system. If the IFCB system is down before the deadline, please email your bid to info@crwconsulting.com or fax it to 918.445.0049. Bids or questions submitted in this fashion will be disqualified if the on-line system is active at the time of submission.
· Bidder must agree to participate in USF Program (AKA “E-rate”) for the corresponding funding year.
· Please include the correct Service Provider Identification Number (SPIN) on your bid.
· By submitting a bid, bidder certifies that the bidder does have a valid (non-red light status) SPIN for the E-rate program at the time of submission. Should the Applicant discover that the bidder is on red light status, or if the FCC classifies the bidder as on red-light status before work is performed and invoices are paid, the contract will be null and void and the applicant will have no payment obligations to the bidder.
· Bidder is expected to provide the lowest corresponding price per E-rate rules. See http://www.usac.org/sl/service-providers/step02/lowest-corresponding-price.aspx for details.
· Contracts must not prohibit SPIN changes.
· Bidder must agree to provide the Applicant the choice of discount methods (SPI or BEAR).
· Bidder will be automatically disqualified if the District determines that the bidding company has offered any employee of the District any individual gift of more than $20 or gifts totaling more than $50 within a 12-month period. This does not apply to the recent FCC exemptions of the Gift Rule for the COVID pandemic.
· All contracts awarded will be contingent upon E-rate funding and final board approval. The applicant may choose to do all or part of the project upon funding notification.
· All contracts awarded under this IFCB bidding process may be voluntarily renewed by the applicant, upon written notice to the provider, for five consecutive one-year terms. Please include this language in your final contract.
· All applicable fees, surcharges, and taxes must be identified on the bid or your bid will be disqualified. E-rate rules require the applicants to evaluate the price of eligible goods and services that will be listed on the 471 application during the competitive bidding process. If the applicant discovers that fees, taxes or surcharges apply but are not listed on the bid (after the time of bid awards) those charges will be the responsibility of the bidding company.
· The winning vendor will be required to complete the USAC approved Item 21 template for the project within 7 working days after notification that the vendor has won the bid.
· DISQUALIFICATION FACTOR INTERNAL CONNECTIONS ALL PROJECTS: Vendors must complete and include the C2 Cover Page with their bid. Bids received without the cover page will be disqualified.
· DISQUALIFICATION FACTOR INTERNAL CONNECTIONS ALL PROJECTS: Service providers are required to bid the entire hardware project/upgrade. Bids for individual components of the project/upgrade will be disqualified.
· DISQUALIFICATION FACTOR INTERNAL CONNECTIONS ALL PROJECTS: Applicant will not accept bids for refurbished equipment. Any bids containing refurbished equipment will be disqualified.
· DISQUALIFICATION FACTOR INTERNAL CONNECTIONS ALL PROJECTS: Bids from companies that include equipment barred by the Federal Communications Commission due to national security risks (such as ZTE or Huawei) will be disqualified.
CATEGORY TWO – INTERNAL CONNECTIONS
VOLUNTARY SITE VISITS
Vendors wishing to bid on any of the Internal Connections Projects may attend one of two voluntary site visits. The site visits will be held on November 9th and November 13th at 8:30AM. Vendors should report to the Bourbon Middle School at 363 Jost Street, Bourbon, MO 65441 and ask for Paul. Vendors are required to wear masks. The district is asking vendors not to attend if they do not feel well.
PROJECT A: NETWORK UPGRADE
Please include installation and configuration costs for all requested equipment. Please include licensing cost for the switches, WAPs and wireless controller. Five year licensing is preferred.
Type of Equipment |
Quantity Vendor Should Bid
|
Preferred Make/Manufacturer |
Cabling |
5 |
Cat6 network drops |
Switches |
30 |
Extreme Networks 48 port with POE (with licensing) or functional equivalent |
UPS/Battery Backup |
16 |
APC, Tripplite or functional equivalent |
Wireless Access Points |
105 |
Extreme Networks (with licensing) or functional equivalent |
Wireless Controller |
1 |
Extreme Networks (with licensing) or functional equivalent |
NOTE: We are requesting switch, WAP, and wireless controller licenses on this IFCB which sometimes may be categorized as BMIC by USAC (the BMIC box on the Form 470 has been checked to cover this scenario).
PROJECT B: CACHING SERVER & FIREWALL
Type of Equipment |
Quantity Vendor Should Bid
|
Preferred Make/Manufacturer |
Caching Server |
1 |
K12USA or functional equivalent |
Firewall Service and Components |
1 |
K12USA or functional equivalent |
PROJECT C: CABLING (WITH INSTALLATION) for new STEM/AG building
Please include pricing for installation. This project is for a new STEM/AG building that has not yet been constructed. There is a building diagram available for download. The district will only be pursuing Project C or Project D, not both.
Type of Equipment |
Quantity Vendor Should Bid
|
Preferred Make/Manufacturer |
Cabling |
60 |
Cat6 network drops |
Cabling |
1 |
Fiber Run. At High School connecting a new building to the High School. Approx 600ft and will start at the High School IDF and terminate inside at the new building (STEM/AG building) |
Cabling |
4 |
48 port Cat6 patch panels |
Cabling |
4 |
Fiber patch panels |
Cabling |
60 |
2ft – 4ft patch cables |
Antennas, Connectors and Related Components |
30 |
Wall plates |
Cabling |
1 |
8,000 ft of Cat6 cabling |
Antennas, Connectors and Related Components |
2 |
GBIC modules |
Antennas, Connectors and Related Components |
2 |
Horizontal wire manager |
Antennas, Connectors and Related Components |
2 |
Boxes of Cat6 jacks |
Antennas, Connectors and Related Components |
50 |
Keystone jacks |
Antennas, Connectors and Related Components |
50 |
Raceways (conduit) |
Rack |
1 |
Tripplite or functional equivalent |
PROJECT D: CABLING (NO INSTALLATION) for new STEM/AG building
No installation is being requested for this Project – this is for equipment only. This project is for a new STEM/AG building that has not yet been constructed. There is a building diagram available for download. The district will only be pursuing Project C or Project D, not both.
Type of Equipment |
Quantity Vendor Should Bid
|
Preferred Make/Manufacturer |
Cabling |
60 |
Cat6 network drops |
Cabling |
1 |
Fiber Run. At High School connecting a new building to the High School. Approx 600ft and will start at the High School IDF and terminate inside at the new building (STEM/AG building) |
Cabling |
4 |
48 port Cat6 patch panels |
Cabling |
4 |
Fiber patch panels |
Cabling |
60 |
2ft – 4ft patch cables |
Antennas, Connectors and Related Components |
30 |
Wall plates |
Cabling |
1 |
8,000 ft of Cat6 cabling |
Antennas, Connectors and Related Components |
2 |
GBIC modules |
Antennas, Connectors and Related Components |
2 |
Horizontal wire manager |
Antennas, Connectors and Related Components |
2 |
Boxes of Cat6 jacks |
Antennas, Connectors and Related Components |
50 |
Keystone jacks |
Antennas, Connectors and Related Components |
50 |
Raceways (conduit) |
Rack |
1 |
Tripplite or functional equivalent |
DISQUALIFICATION FACTOR INTERNAL CONNECTIONS ALL PROJECTS: Vendors must complete and include the C2 Cover Page with their bid. Bids received without the cover page will be disqualified.
DISQUALIFICATION FACTOR INTERNAL CONNECTIONS ALL PROJECTS: Service providers are required to bid entire hardware project/upgrade. Bids for individual components of a single project will be disqualified.
DISQUALIFICATION FACTOR INTERNAL CONNECTIONS ALL PROJECTS: Applicant will not accept bids for refurbished equipment. Any bids containing refurbished equipment will be disqualified.
DISQUALIFICATION FACTOR INTERNAL CONNECTIONS ALL PROJECTS: Bids from companies that include equipment barred by the Federal Communications Commission due to national security risks (such as ZTE or Huawei) will be disqualified.
Building_Diagram.jpg |
Crawford_C2_COVER_PAGE.pdf |
2021_C2_Bidding_Instructions91.pdf |
Answer:
Minimum of 1500VA. No special plug, standard plugs in current locations.
Answer:
1) No
2) Rack Mounted
3) Minimum 1500VA
4a) Open
4b) Minimum 20U
4c) Wall-mount
Answer:
I'm not familiar with fiber installs too much, so we are looking towards vendor recommendations (as long as they are cost-effective for our needs). We encourage you to attend a walkthrough.
Fiber run will be inside and at top of ceiling/above tiles.
Wall-mounted rack.
Answer:
Yes, 2 boxes of 50 count RJ45 connectors Cat 6
50 keystone jacks in total.
Fiber run looking at vendor recommendations as long as they are cost-effective for our needs. We encourage you to attend a walkthrough.
Patch Panel, 12 port
Answer:
No, we did not request leased/managed equipment (MIBS) on this IFCB or 470.