All bid deadlines are 11:59pm Pacific Time the date of the bid deadline listed unless otherwise noted.

school Oklahoma Union ISD
IFCB Posted : Nov 7, 2017
Bid Deadline : Tuesday, Dec 12, 2017

Questions Due By : Friday, Nov 17, 2017
Applicant Address : South Coffeyville, OK 74072
IFCB ID : 180003725

IFCB Requirements :
·         All Questions and Bids must be submitted using the on-line IFCB system. If for some reason the system is down before the respective deadline, please email your bid to info@crwconsulting.com or fax it to 918.445.0049. Bids or questions submitted in this fashion will be disqualified if the on-line system is active at the time of submission.
 
·         Bidder must agree to participate in USF Program (AKA “E-rate”) for the corresponding funding year.
 
·         Please include the correct Service Provider Identification Number (SPIN) on your bid.
 
·         By submitting a bid, bidder certifies that the bidder does have a valid (non-red light status) SPIN for the E-rate program at the time of submission. Should the Applicant discover that the bidder is on red light status, or if the FCC classifies the bidder as on red-light status before work is performed and invoices are paid, the contract will be null and void and the applicant will have no payment obligations to the bidder.
 
·         Bidder is expected to provide the lowest corresponding price per E-rate rules.  See http://www.usac.org/sl/service-providers/step02/lowest-corresponding-price.aspx for details.
 
·         Contracts must not prohibit SPIN changes.
 
·         Bidder must agree to provide the Applicant the choice of discount methods (SPI or BEAR).
 
·         Bidder will be automatically disqualified if the District determines that the bidding company has offered any employee of the District any individual gift of more than $20 or gifts totaling more than $50 within a 12 month period.
 
·         All contracts awarded will be contingent upon E-rate funding and final board approval.  The applicant may choose to do all or part of the project upon funding notification.
 
·         All contracts awarded under this IFCB bidding process may be voluntarily renewed by the applicant, upon written notice to the provider, for five consecutive one year terms. Please include this language in your final contract.
 
·         All applicable fees, surcharges, and taxes must be identified on the bid. E-rate rules require the applicants to evaluate the price of eligible goods and services that will be listed on the 471 application during the competitive bidding process. Fees and surcharges that apply but are not listed on the bid will be the responsibility of the bidding company, should their bid be awarded.
 
·         E-rate rules require applicants to evaluate the cost of eligible goods and services, and to cost-allocate out the amount for ineligible services from their funding request. If your company will be bidding internet access service, please identify the amount to be cost-allocated out for the ineligible services – email service, web hosting, content filtering, or other bundled ineligible services.
 
·         DISQUALIFICATION FACTOR INTERNET: Bidders who are not eligible to provide OUSF support will be disqualified. By placing a bid for these services the bidder agrees to file the completed OUSF affidavit within 90 days of the start of service (applicant agrees to complete their portion in a timely fashion after the request for completion by the winning bidder).
 
·         INTERNET ACCESS DISQUALIFICATION FACTOR: Any and all installation charges must be identified on your bid. If you submit a bid indicating that installation charges may apply without listing those charges, we will consider your bid incomplete and disqualify your bid.
·         The winning vendor will be required to complete the USAC approved Item 21 template for the project within 7 working days after notification that the vendor has won the bid.
·         DISQUALIFICATION FACTOR BMIC: Service providers are required to bid the entire hardware project/upgrade.  Bids for individual components of the project/upgrade will be disqualified.
·         DISQUALIFICATION FACTOR BMIC: Vendors must complete and include the C2 Cover Page with their bid. Bids received without the cover page will be disqualified.
DISQUALIFICATION FACTOR BMIC - Maintenance bids listing only an hourly rate and not a monthly or annual total will be disqualified.  Vendors quoting an hourly rate are required to also a) confirm that you have the ability/expertise to maintain all of the equipment listed and b) propose a number of hours at a particular rate monthly to properly maintain the entire list of equipment.  Bids that contain only hourly rates, without confirmation that the company can service the list of equipment, or without a monthly total will be disqualified. 

Services and Equipment Requested :
UPDATE: 12/04/17 3:10PM- The bid deadline has been extended to 12/12/17.


Internet Access – Minimum 100Mb bandwidth, maximum 5Gbps bandwidth. Applicant is specifically requesting bids for 200 Mb and 300 Mb bandwidths.  The terminating address for this circuit is Oklahoma Union Elementary Building at the intersection of US 169 and state Highway 10 west, South Coffeyville, OK 74072; (918) 255.  E-rate rules require applicants to evaluate the cost of eligible goods and services, and to cost-allocate out the amount for ineligible services from their funding request.  If your company will be bidding internet access service, please identify the amount to be cost-allocated out for the ineligible services – email service, web hosting, content filtering, or other bundled ineligible services. 

 
NOTE: Per USAC’s current guidance about applying for Internet access this applicant is checking the Leased Lit Fiber, Internet Access: ISP Service only and Internet Access and Transport Bundled.
NOTE: Applicant will accept any technologies bid. It is our intention to meet all OUSF Fair and Open Competitive Bidding requirements. If you are a NECA/tariffed company, bids for your tariffed rates are allowed. If any of the specified bandwidth speeds are not a tariffed/NECA rate, please bid the closest rate you have available, within the limits of the bandwidth range specified on the 470.

 
DISQUALIFICATION FACTOR INTERNET: Bidders who are not eligible to provide OUSF support will be disqualified. By placing a bid for these services the bidder agrees to file the completed OUSF affidavit within 90 days of the start of service (applicant agrees to complete their portion in a timely fashion after the request for completion by the winning bidder).
 
 
INTERNET ACCESS DISQUALIFICATION FACTOR: Any and all installation charges must be identified on your bid. If you submit a bid indicating that installation charges may apply without listing those charges, we will consider your bid incomplete and disqualify your bid.
 
 
 
C2
 
 
 
 
Type of Equipment
School Name
Specific Quantity
 
Preferred Make/Manufacturer
Cabling
Elementary
240
Cat5 Drops
Cabling
Elementary
5
Multimode Fiber        
Antennas, Connectors and Related Components
Elementary
144
Leviton Cat5E Patch Panels
Antennas, Connectors and Related Components
Elementary
4
Extreme 10619 Transceivers
Switches        
Elementary
9
Extreme X440-48port
Switches        
Elementary
2
Extreme X8-8port
UPS/Battery Backups
Elementary
4
APC Smart UPS 750
UPS/Battery Backups
Elementary
3
APC Smart UPS 1500
UPS/Battery Backups
Elementary
1
Tripplite SmartPro SMX1000RT2U
Wireless Access Points
Elementary
6
Aruba 105
Firewall Service and Components
Elementary
1
Juniper SRX340E
 
Type of Equipment
School Name
Specific Quantity
 
Preferred Make/Manufacturer
Antennas, Connectors and Related Components
MS
1
Extreme 1-port GBIC
Antennas, Connectors and Related Components
MS
1
Gen 96-port patch panel
Cabling
MS
100
Cat5 Cable Drops
UPS/Battery Backup
MS
1
APC SmartUPS 750
UPS/Battery Backup
MS
1
Tripplite SmartPro SMX1000RT2U
Switches           
MS
1
Extreme X440-48port
Switches           
MS
1
Extreme X440-24port
Switches           
MS
1
Extreme X440-G2-48port
Wireless Access Points
MS
2
Aruba 205
 
 
Type of Equipment
School Name
Specific Quantity
 
Preferred Make/Manufacturer
Antennas, Connectors and Related Components
HS
2
Leviton 48 port patch panels
Antennas, Connectors and Related Components
HS
2
Extreme 10619 transceivers
Cabling
HS
110
Cat5 Drops
Cabling
HS
1
Multimode Fiber        
Switches       
HS
1
Extreme X440-48port
Switches       
HS
1
Extreme X440-24port
Switches       
HS
2
Extreme X440-G2-48port
UPS/Battery Backups
HS
1
APC 1500
UPS/Battery Backups
HS
1
Tripplite SmartPro SMX1000RT2U
Wireless Access Points
HS
3
Aruba 205
Wireless Access Points
HS
9
Aruba 225
 
DISQUALIFICATION FACTOR BMIC: Service providers are required to bid the entire hardware project/upgrade.  Bids for individual components of the project/upgrade will be disqualified.
DISQUALIFICATION FACTOR BMIC: Vendors must complete and include the C2 Cover Page with their bid. Bids received without the cover page will be disqualified.
DISQUALIFICATION FACTOR BMIC - Maintenance bids listing only an hourly rate and not a monthly or annual total will be disqualified.  Vendors quoting an hourly rate are required to also a) confirm that you have the ability/expertise to maintain all of the equipment listed and b) propose a number of hours at a particular rate monthly to properly maintain the entire list of equipment.  Bids that contain only hourly rates, without confirmation that the company can service the list of equipment, or without a monthly total will be disqualified.
  

There is an additional document associated with this IFCB. Please click the buttons to download the document.

2018C2BiddingInstructions3031.docx
OklahomaUnionC2COVERPAGE51.pdf

Questions Received with Applicant Answers   ( Ask Questions? )




I would like to come out to you're district to look at IT closets and see where all equipment goes. Can you leave a number so I can schedule a walkthrough or will you schedule a walkthrough? Thank you, B

Answer:
 Vendors may come out for a site visit on Tuesday, November 14th at 9 am

I was unable to come to your 11-14-2017 walkthrough due to bad health and I was wanting to know if there is any possible way you can schedule another walkthrough maybe after fall break? Your due Date is not till 12-5-2017 so that would give plenty of time. Thank you for your consideration.

Answer:
 We can allow one more site visit on Friday 11/17/2017 at 9 am

Can you provide a map/Fire plan of the school and where the switches and cable drops will be located? Thank you

Answer:
 We do not have a document that provides that level of detail available, but we encourage you to attend the walkthrough on the 17th

How many hours does the customer have budgeted for maintenance/repair per month?

Answer:
 32 hours. one day per week.