All bid deadlines are 11:59pm Pacific Time the date of the bid deadline listed unless otherwise noted.

school Graham ISD
IFCB Posted : Feb 14, 2017
Bid Deadline : Friday, Mar 24, 2017

Questions Due By : Friday, Feb 24, 2017
Applicant Address : Graham, TX 76450
IFCB ID : 170066098

IFCB Requirements :
·         All Questions and Bids must be submitted using the on-line IFCB system. If for some reason the system is down before the respective deadline, please email your bid to info@crwconsulting.com or fax it to 918.445.0049. Bids or questions submitted in this fashion will be disqualified if the on-line system is active at the time of submission.
 
·         Bidder must agree to participate in USF Program (AKA “E-rate”) for the corresponding funding year.
 
·         Bids must identify all fees and charges (including installation charges, if applicable) that will be assessed to the Applicant to procure the services or equipment included in your bid.
 
·         Please include the correct Service Provider Identification Number (SPIN) on your bid.
 
·         By submitting a bid, bidder certifies that the bidder does have a valid (non-red light status) SPIN for the E-rate program at the time of submission. Should the Applicant discover that the bidder is on red light status, or if the FCC classifies the bidder as on red-light status before work is performed and invoices are paid, the contract will be null and void and the applicant will have no payment obligations to the bidder.
 
·         Bidder is expected to provide the lowest corresponding price per E-rate rules.  See http://www.usac.org/sl/service-providers/step02/lowest-corresponding-price.aspx for details.
 
·         Contracts must not prohibit SPIN changes.
 
·         Bidder must agree to provide the Applicant the choice of discount methods (SPI or BEAR).
 
·         Bidder will be automatically disqualified if the District determines that the bidding company has offered any employee of the District any individual gift of more than $20 or gifts totaling more than $50 within a 12 month period.
 
·         All contracts awarded will be contingent upon E-rate funding and final board approval.  The applicant may choose to do all or part of the project upon funding notification.
 
·         All contracts awarded under this IFCB bidding process may be voluntarily renewed by the applicant, upon written notice to the provider, for five consecutive one year terms. Please include this language in your final contract.
 
·         All applicable fees, surcharges, and taxes must be identified on the bid. E-rate rules require the applicants to evaluate the price of eligible goods and services that will be listed on the 471 application during the competitive bidding process. Fees and surcharges that apply but are not listed on the bid will be the responsibility of the bidding company, should their bid be awarded.
 
·         If the Applicant is requesting bids for equipment with specific make and model numbers listed, the Applicant will also accept bids for functionally equivalent equipment.
·         The winning vendor will be required to complete the USAC approved Item 21 template for the project within 7 working days after notification that the vendor has won the bid.
·         DISQUALIFICATION FACTOR INTERNAL CONNECTIONS/BMIC: Service providers are required to bid the entire hardware project/upgrade.  Bids for individual components of the project/upgrade will be disqualified.
 
·         DISQUALIFICATION FACTOR INTERNAL CONNECTIONS/BMIC: Vendors must complete and include the C2 Cover Page with their bid. Bids received without the cover page will be disqualified.
 
·         DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Applicant will not accept bids for refurbished equipment. Any bids containing refurbished equipment will be disqualified.
 
·         DISQUALIFICATION BMIC - Maintenance bids listing only an hourly rate and not a monthly or annual total will be disqualified.  Vendors quoting an hourly rate are required to also a) confirm that you have the ability/expertise to maintain all of the equipment listed and b) propose a number of hours at a particular rate monthly to properly maintain the entire list of equipment.  Bids that contain only hourly rates, without confirmation that the company can service the list of equipment, or without a monthly total will be disqualified. 

Services and Equipment Requested :
SIP Trunk for approximately 25 simultaneous calls. Minimum amount of bandwidth requested: 3Mb.  Please bid at 3Mb and 10Mb.  If pricing is available for bandwidth ranges between those to values please provide that pricing.  Terminating address for SIP Trunk will be 1000 Brazos Street, Graham, TX 76450; (940) 549.
 
C2
 
There is another document associated with this IFCB available for download that details the equipment the applicant wishes to purchase.  The document lists equipment that the applicant prefers – they will also accept functional equivalents of said items. 

There is another document associated with this IFCB available for download that lists the equipment to be maintained. 
 
 
CATEGORY TWO VOLUNTARY WALKTHROUGH
Vendors wishing to bid on C2 can attend a voluntary site visit one day February 17TH or 24th, 2017 at 10am. Vendors will meet at Graham High School Office located at 1000 Brazos St. Graham, TX, 76450. Vendors should RSVP to Jayne Beale at jayne.beale@grahamisd.com to confirm attendance to the site visit on one of those dates. THIS EMAIL IS TO RSVP ONLY. ALL QUESTIONS AND BIDS MUST STILL BE SUBMITTED VIA THE IFCB. BIDS NOT SUBMITTED VIA THE IFCB WILL BE DISQUALIFIED.
 
Project Narrative

We currently have Xirrus units installed that cover several classrooms at the high school. (All other campuses have Xirrus arrays in each classroom). Through this project, we are looking to increase density in each classroom at the high school by installing an array per instructional classroom. The current Xirrus units will be positioned in other parts of the building or other areas in the district. The 1500w power supplies will need to be added to supply sufficient power for POE+ as well as a switch module.
Cable drops, Xirrus arrays, and switch module for POE+ will all need to be installed and configured.  Power supplies for each switch will also need to be installed.
Will need 12 power supplies. Each of the 6 currently installed switches requires 2 power supplies. The currently installed power supplies are 875w and do not have enough power to support PoE+, which new access points will need for power. Because of this, all of the switches will need to have their 875w power supplies replaced with a 1500w power supply, 2 per switch.
The currently installed switches are "modular". They are chassis that have modules installed in them for network connectivity.  The modules can be 24 port copper, fiber, or a mix of both. Depending on the switch, there can be from 6 to 8 slots in the chassis that can be populated with modules. All of the switches currently have an unused 24 port copper PoE+ module installed except for one. This switch has an open bay that needs a 24 port copper PoE+ module installed in it. 
 
DISQUALIFICATION FACTOR INTERNAL CONNECTIONS/BMIC: Service providers are required to bid the entire hardware project/upgrade.  Bids for individual components of the project/upgrade will be disqualified.
 
DISQUALIFICATION FACTOR INTERNAL CONNECTIONS/BMIC: Vendors must complete and include the C2 Cover Page with their bid. Bids received without the cover page will be disqualified.
 
DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Applicant will not accept bids for refurbished equipment. Any bids containing refurbished equipment will be disqualified.
DISQUALIFICATION BMIC - Maintenance bids listing only an hourly rate and not a monthly or annual total will be disqualified.  Vendors quoting an hourly rate are required to also a) confirm that you have the ability/expertise to maintain all of the equipment listed and b) propose a number of hours at a particular rate monthly to properly maintain the entire list of equipment.  Bids that contain only hourly rates, without confirmation that the company can service the list of equipment, or without a monthly total will be disqualified. 

There is an additional document associated with this IFCB. Please click the buttons to download the document.

2017C2BiddingInstructions7114.pdf
GrahamC2attachment.xlsx
GrahamC2COVERPAGE.pdf

Questions Received with Applicant Answers   ( Ask Questions? )




Hello, We are an AVAYA Partner. Will you accept an AVAYA bid? Are you only accepting bids for the switch module for HP switch for POE+? ...or switches as well?

Answer:
 E-rate rules require applicants to accept bids for “functionally equivalent” equipment and we will of course follow their procedures. That being said we already have a centralized management system for Xirrus, by Xirrus, that manages the current wireless at that campus and the rest of the district. Some of the currently installed Xirrus arrays will still be used there, just repositioned to other areas.

 

As for the switch, I only want a POE+ module for the currently installed switch. There is room in the chassis of the currently installed switch for a module and all of the switches in the rest of the district are HP