All bid deadlines are 11:59pm Pacific Time the date of the bid deadline listed unless otherwise noted.

school Taloga ISD
IFCB Posted : Nov 8, 2019
Bid Deadline : Friday, Dec 20, 2019

Questions Due By : Friday, Nov 22, 2019
Applicant Address : Taloga, OK 73667
IFCB ID : 200004128

IFCB Requirements :
All Questions and Bids must be submitted using the on-line IFCB system. If the IFCB system is down before the deadline, please email your bid to info@crwconsulting.com or fax it to 918.445.0049. Bids or questions submitted in this fashion will be disqualified if the on-line system is active at the time of submission.
Bidder must agree to participate in USF Program (AKA “E-rate”) for the corresponding funding year.
 
Please include the correct Service Provider Identification Number (SPIN) on your bid.
By submitting a bid, bidder certifies that the bidder does have a valid (non-red light status) SPIN for the E-rate program at the time of submission. Should the Applicant discover that the bidder is on red light status, or if the FCC classifies the bidder as on red-light status before work is performed and invoices are paid, the contract will be null and void and the applicant will have no payment obligations to the bidder.
 
Bidder is expected to provide the lowest corresponding price per E-rate rules.  See http://www.usac.org/sl/service-providers/step02/lowest-corresponding-price.aspx for details.
 
Contracts must not prohibit SPIN changes.
 
Bidder must agree to provide the Applicant the choice of discount methods (SPI or BEAR).
 
Bidder will be automatically disqualified if the District determines that the bidding company has offered any employee of the District any individual gift of more than $20 or gifts totaling more than $50 within a 12 month period.
 
All contracts awarded will be contingent upon E-rate funding and final board approval.  The applicant may choose to do all or part of the project upon funding notification.
 
All contracts awarded under this IFCB bidding process may be voluntarily renewed by the applicant, upon written notice to the provider, for five consecutive one year terms. Please include this language in your final contract. 
 
All applicable fees, surcharges, and taxes must be identified on the bid or your bid will be disqualified. E-rate rules require the applicants to evaluate the price of eligible goods and services that will be listed on the 471 application during the competitive bidding process. If the applicant discovers that fees, taxes or surcharges apply but are not listed on the bid (after the time of bid awards) those charges will be the responsibility of the bidding company.
 
E-rate rules require applicants to evaluate the cost of eligible goods and services and to cost-allocate out the amount for ineligible services from their funding request. If your company will be bidding internet access service, please identify the amount to be cost-allocated out for the ineligible services – email service, web hosting, content filtering, or other bundled ineligible services.
 
DISQUALIFICATION FACTOR INTERNET: Bidders who are not eligible to provide OUSF support will be disqualified. By placing a bid for these services the bidder agrees to file the completed OUSF affidavit within 90 days of the start of service (applicant agrees to complete their portion in a timely fashion after the request for completion by the winning bidder).
 
INTERNET ACCESS DISQUALIFICATION FACTOR: Any and all installation charges must be identified on your bid. If you submit a bid indicating that installation charges may apply without listing those charges, we will consider your bid incomplete and disqualify your bid.
 
The winning vendor will be required to complete the USAC approved Item 21 template for the project within 7 working days after notification that the vendor has won the bid. 
 
DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Vendors must complete and include the C2 Cover Page with their bid. Bids received without the cover page will be disqualified.
 
DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Service providers are required to bid the entire hardware project/upgrade.  Bids for individual components of the project/upgrade will be disqualified.
 
DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: It will be the bidder’s responsibility to provide documentation about the compatibility requirements listed in this IFCB. Vendors that submit bids without documentation demonstrating the required compatibility listed in this IFCB will have their bids disqualified, unless that vendor has bid the preferred make/model number listed.
 
DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Vendors who wish to bid must attend one of two mandatory site visits. Vendors who submit a bid but have not attended a meeting will be disqualified.
 
DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Applicant will not accept bids for refurbished equipment. Any bids containing refurbished equipment will be disqualified.
 
DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Bids that include equipment that were manufactured for use outside of the United States will be disqualified.
 
DISQUALIFICATION FACTOR BMIC: Service providers are required to bid the entire hardware project/upgrade.  Bids for individual components of the project/upgrade will be disqualified.
 
DISQUALIFICATION FACTOR BMIC: Vendors must complete and include the C2 Cover Page with their bid. Bids received without the cover page will be disqualified.
 
DISQUALIFICATION FACTOR BMIC: Maintenance bids listing only an hourly rate and not a monthly or annual total will be disqualified.  Vendors quoting an hourly rate are required to also a) confirm that you have the ability/expertise to maintain all of the equipment listed and b) propose a number of hours at a particular rate monthly to properly maintain the entire list of equipment.  Bids that contain only hourly rates, without confirmation that the company can service the list of equipment, or without a monthly total will be disqualified.  

Services and Equipment Requested :
Category One
 
Internet Access – Applicant currently has 100Mb bandwidth, and will accept bids up to 500Mb. Applicant is specifically requesting bids for 200Mb and 300Mb.  The terminating address for this circuit is 500 W. Ruble, Taloga, OK 73667; (580) 328.  E-rate rules require applicants to evaluate the cost of eligible goods and services, and to cost-allocate out the amount for ineligible services from their funding request.  If your company will be bidding internet access service, please identify the amount to be cost-allocated out for the ineligible services – email service, web hosting, content filtering, or other bundled ineligible services. 
 
NOTE: Applicant will accept any technologies bid. It is our intention to meet all OUSF Fair and Open Competitive Bidding requirements. If you are a NECA/tariffed company, bids for your tariffed rates are allowed. If any of the specified bandwidth speeds are not a tariffed/NECA rate, please bid the closest rate you have available, within the limits of the bandwidth range specified on the 470.
 
NOTE: Per USAC’s current guidance about applying for Internet access this applicant is checking the Leased Lit Fiber, Internet Access: ISP Service only and Internet Access and Transport Bundled. 
 
DISQUALIFICATION FACTOR INTERNET ACCESS: Bidders who are not eligible to provide OUSF support will be disqualified. By placing a bid for these services the bidder agrees to file the completed OUSF affidavit within 90 days of the start of service (applicant agrees to complete their portion in a timely fashion after the request for completion by the winning bidder).
 
INTERNET ACCESS DISQUALIFICATION FACTOR: Any and all installation charges must be identified on your bid. If you submit a bid indicating that installation charges may apply without listing those charges, we will consider your bid incomplete and disqualify your bid.
 
 
Internal Connections
 
MANDATORY SITE VISIT
 
Vendors wishing to submit bids for category two projects must attend one of two mandatory site visits. The site visits will be held on November 18th and November 21st anytime between 9AM-4PM. Vendors will meet at 500 W. Ruble, Taloga, OK 73667. Bids from vendors who did not attend either of the site visits will be disqualified.
 
Project Narrative
 
The District is updating internet to all campus buildings. Installation, configuration, and activation will be needed. 

Type of Equipment

School Name

Quantity Vendor Should Bid

 

Preferred Make/Manufacturer

Firewall Service and Components

District Shared

1

Sophos or functional equivalent

Racks

District Shared

2

No preference

Switches

District Shared

4

UniFi 8-port or functional equivalent

Switches

District Shared

2

UniFi 24-port or functional equivalent

Switches

District Shared

1

UniFi 48-port or functional equivalent

UPS/Battery Backup

District Shared

7

No preference

Wireless Access Points

District Shared

15

Unifi or functional equivalent

Wireless Controller

District Shared

1

No preference


NOTE:  The BMIC box has been checked on the 470 in the event that your licenses are considered BMIC (not IC) by USAC.  Bid those costs, if any, under Internal Connections on the cover page.
 
Compatibility Requirement
 
All equipment must be compatible with Sophos firewall and existing UniFi equipment. 
 
DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: It will be the bidder’s responsibility to provide documentation about the compatibility requirements listed in this IFCB. Vendors that submit bids without documentation demonstrating the required compatibility listed in this IFCB will have their bids disqualified, unless that vendor has bid the preferred make/model number listed.
 
DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Vendors must complete and include the C2 Cover Page with their bid. Bids received without the cover page will be disqualified.
 
DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Service providers are required to bid the entire hardware project/upgrade.  Bids for individual components of the project/upgrade will be disqualified.
 
DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Vendors who wish to bid must attend one of two mandatory site visits. Vendors who submit a bid but have not attended a meeting will be disqualified.
 
DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Applicant will not accept bids for refurbished equipment. Any bids containing refurbished equipment will be disqualified.
 
DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Bids that include equipment that were manufactured for use outside of the United States will be disqualified.
 
Basic Maintenance of Internal Connections

Type of Equipment

School Name

Quantity Vendor Should Bid

 

Preferred Make/Manufacturer

Firewall Service and Components

District Shared

1

Sophos


DISQUALIFICATION FACTOR BMIC: Service providers are required to bid the entire hardware project/upgrade.  Bids for individual components of the project/upgrade will be disqualified.
 
DISQUALIFICATION FACTOR BMIC: Vendors must complete and include the C2 Cover Page with their bid. Bids received without the cover page will be disqualified.
 
DISQUALIFICATION FACTOR BMIC: Maintenance bids listing only an hourly rate and not a monthly or annual total will be disqualified.  Vendors quoting an hourly rate are required to also a) confirm that you have the ability/expertise to maintain all of the equipment listed and b) propose a number of hours at a particular rate monthly to properly maintain the entire list of equipment.  Bids that contain only hourly rates, without confirmation that the company can service the list of equipment, or without a monthly total will be disqualified.  
 

There is an additional document associated with this IFCB. Please click the buttons to download the document.

2020C2BiddingInstructions2.pdf
TalogaC2COVERPAGE.pdf

Questions Received with Applicant Answers   ( Ask Questions? )




Mandatory Site Visit - Do we need to schedule a specific time on November 18, 2019 or November 21, 2019 between 9:00am and 4:00pm?

Answer:
 Show up at either 10 am or 2 pm on either day

Hi Chris – https://www.fundsforlearning.com/470/rfp.php?470=200004128&file=Taloga+IFCB.pdf I have a few questions regarding your C2 E-Rate request. UPSs * What form (rack mount or tower) UPS they would like? * Type of UPS? (Offline, Line interactive, or Double Conversion) * how many watts they need? * run time? * Input/output voltages? * Power distribution required/Outlets required? Racks * What are the width and depth requirements? * Wall mount or stand alone? * How much U space is needed? * Locking or non-locking?

Answer:
 

Here are the items we can answer.  The other items you can see at the walkthrough.

 

U rack Mount

CyberPower OR500LCDRM1U Smart App LCD UPS System, 500VA/300W, 6 Outlets, AVR, 1U Rackmount: Uninterruptible Power Supply (UPS) (or functional equiv.)

Wall mount Rack, 9U

Have lots of space for racks not an issue. Stand alone and locked in place

Would like to schedule November 21, 2019 at 10:00 for our site visit.

Answer:
 

That works – vendors can show up at either of the specified times on either day.