All bid deadlines are 11:59pm Pacific Time the date of the bid deadline listed unless otherwise noted.

school North Park School District R-1
IFCB Posted : Oct 28, 2019
Bid Deadline : Thursday, Dec 12, 2019

Questions Due By : Thursday, Nov 14, 2019
Applicant Address : Walden, CO 80480
IFCB ID : 200002831

IFCB Requirements :
All Questions and Bids must be submitted using the on-line IFCB system. If the IFCB system is down before the deadline, please email your bid to info@crwconsulting.com or fax it to 918.445.0049. Bids or questions submitted in this fashion will be disqualified if the on-line system is active at the time of submission.
Bidder must agree to participate in USF Program (AKA “E-rate”) for the corresponding funding year.
 
Please include the correct Service Provider Identification Number (SPIN) on your bid.
 
By submitting a bid, bidder certifies that the bidder does have a valid (non-red light status) SPIN for the E-rate program at the time of submission. Should the Applicant discover that the bidder is on red light status, or if the FCC classifies the bidder as on red-light status before work is performed and invoices are paid, the contract will be null and void and the applicant will have no payment obligations to the bidder.
 
Bidder is expected to provide the lowest corresponding price per E-rate rules.  See http://www.usac.org/sl/service-providers/step02/lowest-corresponding-price.aspx for details.
 
Contracts must not prohibit SPIN changes.
 
Bidder must agree to provide the Applicant the choice of discount methods (SPI or BEAR).
 
Bidder will be automatically disqualified if the District determines that the bidding company has offered any employee of the District any individual gift of more than $20 or gifts totaling more than $50 within a 12 month period.
 
All contracts awarded will be contingent upon E-rate funding and final board approval.  The applicant may choose to do all or part of the project upon funding notification.
 
All contracts awarded under this IFCB bidding process may be voluntarily renewed by the applicant, upon written notice to the provider, for five consecutive one year terms. Please include this language in your final contract. 
 
All applicable fees, surcharges, and taxes must be identified on the bid or your bid will be disqualified. E-rate rules require the applicants to evaluate the price of eligible goods and services that will be listed on the 471 application during the competitive bidding process. If the applicant discovers that fees, taxes or surcharges apply but are not listed on the bid (after the time of bid awards) those charges will be the responsibility of the bidding company.
 
LEASED LIT FIBER DISQUALIFICATION FACTOR: Any and all installation charges must be identified on your bid. If you submit a bid indicating that installation charges may apply without listing those charges, we will consider your bid incomplete and disqualify your bid.
 
The winning vendor will be required to complete the USAC approved Item 21 template for the project within 7 working days after notification that the vendor has won the bid. 
 
DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Vendors must complete and include the C2 Cover Page with their bid. Bids received without the cover page will be disqualified.
 
DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Service providers are required to bid the entire hardware project/upgrade.  Bids for individual components of the project/upgrade will be disqualified.
 
DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: It will be the bidder’s responsibility to provide documentation about the compatibility requirements listed in this IFCB. Vendors that submit bids without documentation demonstrating the required compatibility listed in this IFCB will have their bids disqualified, unless that vendor has bid the preferred make/model number listed.
 
DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Applicant will not accept bids for refurbished equipment. Any bids containing refurbished equipment will be disqualified.
 
DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Bids that include equipment that were manufactured for use outside of the United States will be disqualified.
 
DISQUALIFICATION FACTOR BMIC: Service providers are required to bid the entire hardware project/upgrade.  Bids for individual components of the project/upgrade will be disqualified.
 
DISQUALIFICATION FACTOR BMIC: Vendors must complete and include the C2 Cover Page with their bid. Bids received without the cover page will be disqualified.
 
DISQUALIFICATION FACTOR BMIC: Maintenance bids listing only an hourly rate and not a monthly or annual total will be disqualified.  Vendors quoting an hourly rate are required to also a) confirm that you have the ability/expertise to maintain all of the equipment listed and b) propose a number of hours at a particular rate monthly to properly maintain the entire list of equipment.  Bids that contain only hourly rates, without confirmation that the company can service the list of equipment, or without a monthly total will be disqualified. 

Services and Equipment Requested :
UPDATE 11/05/19: Network maps have been added as an attachment.

Category One
 
Leased Lit Fiber- 1Gb WAVE connection from 910 4th Street, Walden, CO 80480; (970) 723; to Steamboat Springs School District located at 325 7th Street, Steamboat Springs, CO 80487; (970) 879.  Please include all installation costs.  Please include pricing for a leased router and leased switches.  Please also include service level agreements with your bid. 
 
LEASED LIT FIBER DISQUALIFICATION FACTOR: Any and all installation charges must be identified on your bid. If you submit a bid indicating that installation charges may apply without listing those charges, we will consider your bid incomplete and disqualify your bid.
 
 
Category Two 
 
Internal Connections
 
VOLUNTARY SITE VISIT
 
Vendors wishing to bid on internal connections can attend a voluntary site visit November 7th or November 14th at 9-10AM, or 1-3PM either day.  Vendors should meet at 910 4th Street, Walden, CO 80480, and check in with Brenda Brown.
 
Project Narrative
 
Our current WAPs have reached their end of life (EOL), therefore, the District will need to upgrade 30 WAPs throughout the school.  Please include service level agreements for this upgrade.  Installation and configuration will be needed. 
 

Type of Equipment

School Name

Quantity Vendor Should Bid

 

Preferred Make/Manufacturer

Wireless Access Points

North Park School

30

Aruba, Meraki, or HP POE, and should include (2) high density WAPs for large areas: gym and library, or functional equivalents.

Wireless Controller

North Park School

1

Aruba, Merkai, or HP or functional equvialent



Compatibility Requirement
 
Requested equipment must be compatible with existing Avaya Ethernet Switches: Ethernet routing switch (4850GTS-PWR+), Ethernet routing switch (4926GTS-PWR+), and Ethernet routing switch (3510GT-PWR+). Our current WAPs are managed with a virtual controller, a physical controller is not present. 
 
DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: It will be the bidder’s responsibility to provide documentation about the compatibility requirements listed in this IFCB. Vendors that submit bids without documentation demonstrating the required compatibility listed in this IFCB will have their bids disqualified, unless that vendor has bid the preferred make/model number listed.
 
DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Vendors must complete and include the C2 Cover Page with their bid. Bids received without the cover page will be disqualified.
 
DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Service providers are required to bid the entire hardware project/upgrade.  Bids for individual components of the project/upgrade will be disqualified.
 
DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Applicant will not accept bids for refurbished equipment. Any bids containing refurbished equipment will be disqualified.
 
DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Bids that include equipment that were manufactured for use outside of the United States will be disqualified.
 
Basic Maintenance of Internal Connections
 

Type of Equipment

School Name

Quantity Vendor Should Bid

 

Preferred Make/Manufacturer

Wireless Access Points

North Park School

30

Aruba, Meraki, or HP POE, and should include (2) high density WAPs for large areas: gym and library

Wireless Controller

North Park School

1

Aruba, Merkai, or HP


DISQUALIFICATION FACTOR BMIC: Service providers are required to bid the entire hardware project/upgrade.  Bids for individual components of the project/upgrade will be disqualified.
 
DISQUALIFICATION FACTOR BMIC: Vendors must complete and include the C2 Cover Page with their bid. Bids received without the cover page will be disqualified.
 
DISQUALIFICATION FACTOR BMIC: Maintenance bids listing only an hourly rate and not a monthly or annual total will be disqualified.  Vendors quoting an hourly rate are required to also a) confirm that you have the ability/expertise to maintain all of the equipment listed and b) propose a number of hours at a particular rate monthly to properly maintain the entire list of equipment.  Bids that contain only hourly rates, without confirmation that the company can service the list of equipment, or without a monthly total will be disqualified.  
 
 

There is an additional document associated with this IFCB. Please click the buttons to download the document.

2020C2BiddingInstructions6081.pdf
NorthParkC2COVERPAGE.pdf
NorthParkSchoolNetworkMap.pdf

Questions Received with Applicant Answers   ( Ask Questions? )




1) Will the district consider Ruckus as a manufacturer for the bid? 2) Will the district be accepting demos? 3) does the district favor cloud management over on prem? 4) is it possible to get a map of the building to do a proper heat map? 5) Is all the wiring cat5e or cat 6? 6) Does the district want AX Aps or AC wave 2?

Answer:
 1) Yes, the district will consider Ruckus as a manufacturer.

2)  No, the district is not accepting demos.

3) The district definitely favors cloud management over on premise but will accept bids for any cost-effective solution

4) See the network map that was uploaded to the IFCB

5) All wiring is cat5e

6) AX 