MANDATORY SITE VISIT
Vendors wishing to bid on internal connections must attend a mandatory site visit either November 29, 2017 or December 5, 2017 both beginning at 8:30am. Vendors will meet at 200 W Oak St., El Dorado, AR 71730. Bids from vendors who did not attend either of the site visits will be disqualified.
Type of Equipment |
School Name |
Specific Quantity
|
Preferred Make/Manufacturer |
Cabling/drops |
Hugh Goodwin ES |
346 drops |
Leviton or functional equivalent |
Rack |
Hugh Goodwin ES |
1 |
Intellinet (42U Active Cooled Cabinet) or functional equivalent |
Additional information is below and a floor plan is available to download. Applicant will accept bids for functional equivalents.
4-Jack-6110G-RL6,1-Jack-6110G-RC6,1-Wall Plate-42080-6IS, When Surface Mount, Box 42777-1IA
3-Jack-6110G-RL6,1-Jack-6110G-RC6,1-Wall Plate-42080-3TS, When Surface Mount, Box 42777-1IA
2-Jack-6110G-RL6,1-Jack-6110G-RC6,1-Wall Plate-42080-2IS, When Surface Mount, Box 42777-1IA
1-Jack-6110G-RP6, 1-Jack-6110G-RY6, Mount Only Flush
Patch Panel Types – 6910G-U48 and/or 6910G-U24
42U Active Cooled Cabinet Part #713269 3-Fan Ventilation Unit for 19” Racks part #712668
DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Vendors must complete and include the C2 Cover Page with their bid. Bids received without the cover page will be disqualified.
FloorPlan.pdf |
C2COVERPAGE28.pdf |
ElDoradoQA.docx |
ElDoradoFloorPlansVisio |
QuestionsfromWalkthroughonDec5.pdf |
Answer:
All wall jacks, cabling, and patch panel jacks need to be the same color.
Answer:
Yes,Enterasys LC, or functional equivalent.
Answer:
A Visio diagram of the floor plans has been added as an attachment to the IFCB.
Answer:
The part number is for a V-Shaped Leviton Patch Panel that allows you to place Jacks into Patch Panel to match the wiring color. Any information indicating otherwise is to be disregarded.
Answer:
Additional single gang boxes are to be used.
Answer:
Additional single gang boxes are to be used.
Answer:
If the run length is less than 90 feet exterior grade CAT6 can be used(I do not believe there is exterior grade CAT6A, if there is it can be used up to 330 feet) other wise CAT6A in conduit is to be used, whether underground or aerially.
Answer:
For the purposes of the bidding please use the specified jacks in the specified locations.
Answer:
The bid is for the number of drops in the diagram, please check the Visio file available for download from the IFCB page for clarity (it is posted as an attachment on the IFCB, available to view here: https://www.crwconsulting.com/rfp/rpf.php?id=MTc2Mw==). .