All bid deadlines are 11:59pm Pacific Time the date of the bid deadline listed unless otherwise noted.

school Langston Hughes Academy
IFCB Posted : Mar 18, 2016
Bid Deadline : Friday, Apr 15, 2016

Questions Due By : Friday, Apr 8, 2016
Applicant Address : TULSA, OK 74126
IFCB ID : 160037735

IFCB Requirements :
 ·         All Questions and Bids must be submitted using the on-line IFCB system. If for some reason the system is down before the respective deadline, please email your bid to info@crwconsulting.com or fax it to 918.445.0049. Bids or questions submitted in this fashion will be disqualified if the on-line system is active at the time of submission.
 
·         Bidder must agree to participate in USF Program (AKA “E-rate”) for the corresponding funding year.
 
·         Please include the correct Service Provider Identification Number (SPIN) on your bid.
 
·         By submitting a bid, bidder certifies that the bidder does have a valid (non-red light status) SPIN for the E-rate program at the time of submission. Should the Applicant discover that the bidder is on red light status, or if the FCC classifies the bidder as on red-light status before work is performed and invoices are paid, the contract will be null and void and the applicant will have no payment obligations to the bidder.
 
·         Bidder is expected to provide the lowest corresponding price per E-rate rules.  See http://www.usac.org/sl/service-providers/step02/lowest-corresponding-price.aspx for details.
 
·         Contracts must not prohibit SPIN changes.
 
·         Bidder must agree to provide the Applicant the choice of discount methods (SPI or BEAR).
 
·         Bidder will be automatically disqualified if the District determines that the bidding company has offered any employee of the District any individual gift of more than $20 or gifts totaling more than $50 within a 12 month period.
 
·         All contracts awarded will be contingent upon E-rate funding and final board approval.  The applicant may choose to do all or part of the project upon funding notification.
 
·         All contracts awarded under this IFCB bidding process may be voluntarily renewed by the applicant, upon written notice to the provider, for five consecutive one year terms.
 
 
·         E-rate rules require applicants to evaluate the cost of eligible goods and services, and to cost-allocate out the amount for ineligible services from their funding request. If your company will be bidding bundled data and voice plans, please identify the amount to be cost-allocated out for the ineligible data, text messaging functions or other bundled ineligible services.
 
·         E-rate rules require applicants to evaluate the cost of eligible goods and services, and to cost-allocate out the amount for ineligible services from their funding request. If your company will be bidding local phone service, please identify the amount to be cost-allocated out for the ineligible services - DID lines, voice mail, caller ID, inside wire maintenance, 900 call blocking, or other bundled ineligible services.
 
·         E-rate rules require applicants to evaluate the cost of eligible goods and services, and to cost-allocate out the amount for ineligible services from their funding request. If your company will be bidding internet access service, please identify the amount to be cost-allocated out for the ineligible services – email service, web hosting, content filtering, or other bundled ineligible services.
 
 
·         Bidders for all services and products (except for tariffed telecommunications services or month-to-month services which do not have a related contract) must also submit a contract for products or services.
 
·         If the Applicant is requesting bids for equipment with specific make and model numbers listed, the Applicant will also accept bids for functionally equivalent equipment.
 
 
·         iNTERNET ACCESS DISQUALIFICATION FACTOR:  ANY AND ALL INSTALLATION CHARGES MUST BE IDENTIFIED ON YOUR BID. IF YOU SUBMIT A BID INDICATING THAT INSTALLATION CHARGES MAY APPLY WITHOUT LISTING THOSE CHARGES, WE WILL CONSIDER YOUR BID INCOMPLETE AND DISQUALIFY YOUR BID.
 
·         internet access disqualification factor:  bIDDERS WHO ARE NOT ELIGIBLE TO PROVIDE OUSF SUPPORT WILL BE DISQUALIFIED.
 
·         SERVICE PROVIDERS ARE REQUIRED TO BID THE ENTIRE C2 PROJECT A AND/OR PROJECT B.  BIDS FOR INDIVIDUAL COMPONENTS OF THE PROJECT WILL BE DISQUALIFIED
 
·         DISQUALIFICATION FACTOR: Vendors are required to submit bids via the template “Cat-Two-Internal-Connections–16.1” or “Cat-Two-Basic-Maintenance-Internal-Connections-16.1” or “Cat-Two-Managed-Internal-Broadband-Svcs-16.1” for each individual school that is receiving equipment and a separate template for all shared equipment.  Please name each template for the name of the school and project.  Example:  “Smith Elementary School Wireless Project” or “Wireless project shared equipment for all schools.”  Vendors that do not submit bids in the required template format will be disqualified from the process.
 
·         PROVIDERS WISHING TO BID ON THE CATEGORY TWO PROJECTS MUST ATTEND ONE OF TWO MANDATORY WALKTHROUGHS.  THE FIRST WALKTHROUGH WILL BE TUESDAY, MARCH 29, 2016, AND THE SECOND WALKTHROUGH WILL BE TUESDAY, APRIL 5, 2016.  VENDORS MAY ARRIVE BETWEEN 8:30AM AND 4:30PM ON BOTH DAYS @ 5424 NORTH MADISON AVENUE, TULSA, OK.   BIDS FROM VENDORS WHO DO NOT ATTEND ONE OF THE MANDATORY WALKTHROUGHS WILL BE DISQUALIFIED.
 

Services and Equipment Requested :
UPDATE 4/5/2016: WE HAVE JUST BEEN INFORMED THAT THE SCHOOL WILL HAVE TO MOVE NEXT YEAR TO A NEW ADDRESS. PLEASE SUBMIT BIDS WITH THE SERVICE ADDRESS OF: 1821 E. 66th St. N.  74130.  

Local phone service – Approx 30 lines.   E-rate rules require applicants to evaluate the cost of eligible goods and services, and to cost-allocate out the amount for ineligible services from their funding request. If your company will be bidding local phone service, please identify the amount to be cost-allocated out for the ineligible services - DID lines, voice mail, caller ID, inside wire maintenance, 900 call blocking, or other bundled ineligible services.

Long distance service – Approx 200 minutes used

Internet Access –  100Mb  bandwidth.  The terminating address for this circuit is 5424 N. Madison Ave, Tulsa, OK; (918) 728.  Please include separate pricing for any installation, activation, and/or initial configuration costs.  Please also include separate pricing for maintenance and technical support.  Please also include firewall services and technical support.   If your company will be bidding internet access service, please identify the amount to be cost-allocated out for the ineligible services – email service, web hosting, content filtering, or other bundled ineligible services. 
iNTERNET ACCESS DISQUALIFICATION FACTOR:  ANY AND ALL INSTALLATION CHARGES MUST BE IDENTIFIED ON YOUR BID. IF YOU SUBMIT A BID INDICATING THAT INSTALLATION CHARGES MAY APPLY WITHOUT LISTING THOSE CHARGES, WE WILL CONSIDER YOUR BID INCOMPLETE AND DISQUALIFY YOUR BID.
internet access disqualification factor:  bIDDERS WHO ARE NOT ELIGIBLE TO PROVIDE OUSF SUPPORT WILL BE DISQUALIFIED.
 
CATEGORY TWO DISQUALIFICATION FACTORS:

·         DISQUALIFICATION FACTOR: Vendors are required to submit bids via the template “Cat-Two-Internal-Connections–16.1” or “Cat-Two-Basic-Maintenance-Internal-Connections-16.1” or “Cat-Two-Managed-Internal-Broadband-Svcs-16.1” for each individual school that is receiving equipment and a separate template for all shared equipment.  Please name each template for the name of the school and project.  Example:  “Smith Elementary School Wireless Project” or “Wireless project shared equipment for all schools.”  Vendors that do not submit bids in the required template format will be disqualified from the process.
 
·         SERVICE PROVIDERS ARE REQUIRED TO BID THE ENTIRE C2 PROJECT A AND/OR PROJECT B. BIDS FOR INDIVIDUAL COMPONENTS OF THE PROJECT WILL BE DISQUALIFIED.
 
·         PROVIDERS WISHING TO BID ON THE CATEGORY TWO PROJECTS MUST ATTEND ONE OF TWO MANDATORY WALKTHROUGHS.  THE FIRST WALKTHROUGH WILL BE TUESDAY, MARCH 29, 2016, AND THE SECOND WALKTHROUGH WILL BE TUESDAY, APRIL 5, 2016.  VENDORS MAY ARRIVE BETWEEN 8:30AM AND 4:30PM ON BOTH DAYS @ 5424 NORTH MADISON AVENUE, TULSA, OK.   BIDS FROM VENDORS WHO DO NOT ATTEND ONE OF THE MANDATORY WALKTHROUGHS WILL BE DISQUALIFIED.
 
 
CATEGORY TWO PROJECT DETAILS:
 
There are two Category Two Projects.  Project A is for Internal Connections; Project B is for Basic Maintenance.  Please include pricing for installation, activation, and/or initial configuration costs.  We would like for you to submit your bids in your normal format – a word/excel/PDF as you normally would (in addition to the required templates).  The winning vendor will be required to complete, for each school (and all shared equipment), the 2016 USAC C2 Templates when they become available.   

Questions Received with Applicant Answers   ( Ask Questions? )




• How many of the switches need to be stacked at each location? • Will the new router or switch equipment need to be configured for interoperability with any existing/legacy hardware? * Is there a need for PoE vs PoE+? o If so, please provide details regarding the existing environment including makes/models, Layer-1 connectivity, speeds, and VLAN design • Are there specific capabilities desired of the new firewall, such as web content filtering, etc? • Will the new wireless equipment need to be configured for interoperability with any existing/legacy WiFi infrastructure? o If so, please provide details regarding the existing wireless environment including makes/models, mesh, Layer-1 connectivity, speeds, SSID and VLAN design, authentication, etc. • Are wireless site surveys desired prior to installation? Are there any specifics for the caching server? Do you have a preference on rack type?

Answer:
 Question: • How many of the switches need to be stacked at each location?

3 at each location.

ʉۢ Will the new router or switch equipment need to be configured for interoperability with any existing/legacy hardware?

No.                            

* Is there a need for PoE vs PoE+?

We would like to have the PoE switches

o If so, please provide details regarding the existing environment including makes/models, Layer-1 connectivity, speeds, and VLAN design • Are there specific capabilities desired of the new firewall, such as web content filtering, etc?

 Yes –but please make sure you separate out the costs for content filtering, those costs are not E-rate eligible.

• Will the new wireless equipment need to be configured for interoperability with any existing/legacy WiFi infrastructure?

No.

o If so, please provide details regarding the existing wireless environment including makes/models, mesh, Layer-1 connectivity, speeds, SSID and VLAN design, authentication, etc.

N/A

• Are wireless site surveys desired prior to installation?

No.

 Are there any specifics for the caching server?

 No.

Do you have a preference on rack type?

 6 foot standard.

1.What is your motivation for including caching on your form 470? 2.What are the key elements of your web traffic that you would like to cache? 3.What is the size of your core internet connection in Mbps? 4.How much bandwidth is used at peak times in Mbps? 5.How many devices connect to the internet concurrently at peal times? 6.By how much do you expect/plan to increase your bandwidth capacity & device count in the next 3 years?

Answer:
 Question: 1. What is your motivation for including caching on your form 470?

It is a more efficient way to do it if we have the means.  We may have 300 students doing the same thing.  It offers us to have the website data locally.

 2.What are the key elements of your web traffic that you would like to cache?

We would like to cache youtube sites, motivation sites, homework sites, which would minimize our traffic.

3.What is the size of your core internet connection in Mbps?

50 megabytes for second, but we want to increase it.   

4.How much bandwidth is used at peak times in Mbps?

 90-95%.

 5.How many devices connect to the internet concurrently at peal times?

 80. Right now about 60 devices.  Next year we plan to have over 100 devices.

 6. By how much do you expect/plan to increase your bandwidth capacity & device count in the next 3 years?

We for-see us having four or five computer labs.  We see 200%