All bid deadlines are 11:59pm Pacific Time the date of the bid deadline listed unless otherwise noted.
WinfieldC2List.xlsx |
InternalConnectionsTemplateV15179.xlsm |
BasicMaintenanceTemplateV15150.xlsm |
WinfieldUploads122.zip |
Answer:
48 Port Switches – Quantity – 11 each
POE is not required.
Minimum of 4 ports dual personality to allow for SFP fiber modules.
24 Port Switches – Quantity – 8 each
POE is not required.
Minimum of 4 port dual personality to allow for SFP fiber modules.
Modular Core Switch – Quantity – 1 each
POE is not required.
Minimum of 92 10/100/1000 ports and 6 SFP fiber ports
Answer:
The information we currently have available is on this IFCB and the attachments for the IFCB
Answer:
No, the blue boxes do not represent the IT closets in each building.
The locations of the IT closets in each building:
Primary – IT closet is in the library
Middle School A – IT closet is in the library
Middle School B – IT closet is in the office in the upper hall. It is not labeled on the map but it is in the center of the building adjacent to room 6.
Intermediate – IT closet is in the center of the building directly below the Music Room 20 and to the left and right of the Gym.
Answer:
The locations of the IT closets in each building:
Primary – IT closet is in the library
Middle School A – IT closet is in the library
Middle School B – IT closet is in the office in the upper hall. It is not labeled on the map but it is in the center of the building adjacent to room 6.
Intermediate – IT closet is in the center of the building directly below the Music Room 20 and to the left and right of the Gym.
High School – 3 IT closets. Main closet is in the library. One small rack is in the main office, and another small rack is located in room 310.
1. What type of fiber is required between building? Single mode fiber between Primary and MS A, single mode between MS A and MS B, multimode between Tech Office and MO Options. 12 strand fiber for all runs.
2. Should fiber patch cords be included? Yes. 3 meter fiber patch cords should be included.
3. Should fiber modules be included? Yes. 6 multi-mode fiber modules and 6 single mode 10Gb fiber modules should be included.
4. What type of racks are required? Only 1 3 foot wall mount rack should will be required to be installed in the MO Options building.
5. What type of network do you currently use? Flat network
6. What type of fiber connectors should be used? LC fiber connectors
7. What are the switch requirements? Switches should be full-layer 3 and provided multicast routing
8. Is redundant power supply required for all switches? Only the core switch requires a redundant power supply.
Answer:
The packet distributed at the walk-through included maps of the high school and intermediate buildings, however these two buildings are not part of any of the cabling projects.
Answer:
The existing HP 5412 will be replaced. At this time we have not determined the location of the modular core switch. The invitation to bid specifies the following:
Modular Core Switch – Quantity – 1 each
POE is not required.
Minimum of 92 10/100/1000 ports and 6 SFP fiber ports
A previous question addressed the number of fiber modules required for the bid. Additional 10GB fiber modules are not required for the core switch.
Should fiber modules be included? Yes. 6 multi-mode fiber modules and 6 single mode 10Gb fiber modules should be included.